ArticleRespiratory research & clinical practice2026
Agreement between spirometric quality reviewers in an epidemiological study.
Article in Respiratory research & clinical practice, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Objective: . Spirometry is the gold standard among pulmonary function tests, with acceptability criteria established to ensure reliable results. However, variability in the interpretation of spirometry by trained reviewers remains unexplored. This study assessed agreement among trained reviewers regarding spirometric acceptability and its components, including the number of acceptable maneuvers, predominant defect, and repeatability. Methods: . Spirometries from 3,982 adults (≥40 years) participating in an epidemiological study across six cities in Argentina were independently reviewed by junior reviewers (JRs) and adjudicated by senior reviewers (SRs), following the 2005 ATS/ERS guidelines. Agreement was analyzed using Cohen's kappa, McNemar's test, and proportion comparisons. Results: . A total of 7,964 pre- and post-bronchodilator spirometries were analyzed. Agreement on overall acceptability between JRs was 76% and 84% in two independent reviewer teams (RvTa and RvTb, respectively). Agreement on specific defects was highest for numerical criteria, such as insufficient expiratory time (k=0.61) and excessive back-extrapolated volume (BEV; k=0.52), but lower for subjective criteria, including weak effort (k=0.19) and cough in the first second (k=0.36). No agreement was observed for glottic closure (k=0). SR adjudication increased the proportion of acceptable tests from 54% to 65%. Conclusions: Reviewer variability significantly affects spirometric acceptability, with numerical criteria achieving higher agreement than subjective assessments. These discrepancies have implications for large-scale studies, data quality, and automated algorithm development. Cross-checking reviews is recommended to enhance reliability. Further standardization of acceptability criteria is warranted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.