Evidence map›Paper›PMID 42740726›Full record

ArticleJournal of the American Academy of Audiology2026

Comparison of Auditory Brainstem Responses Recorded from Three Different Clinical Systems.

Jennifer Chapman, Tyler Weaver, Sangamanatha Ankmnal Veeranna, Charles Marx

Abstract readComparative Study
In one paragraph

Article in Journal of the American Academy of Audiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jennifer ChapmanSchool of Speech and Hearing Sciences, The College of Nursing Health and Professions, The University of Southern Mississippi, Hattiesburg, MS.
Tyler WeaverSchool of Speech and Hearing Sciences, The College of Nursing Health and Professions, The University of Southern Mississippi, Hattiesburg, MS.
Sangamanatha Ankmnal VeerannaSchool of Speech and Hearing Sciences, The College of Nursing Health and Professions, The University of Southern Mississippi, Hattiesburg, MS.
Charles MarxSchool of Speech and Hearing Sciences, The College of Nursing Health and Professions, The University of Southern Mississippi, Hattiesburg, MS.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The auditory brainstem response (ABR) test is used to estimate hearing thresholds and for neurodiagnostic purposes. ABRs can be recorded for traditional stimuli such as broadband clicks and frequency-specific tone bursts (0.5, 1, 2, and 4 kHz). Recently, chirp stimuli (broadband and narrowband chirps [0.5, 1, 2, and 4 kHz]) have been recommended to be used to record ABRs. Purpose: There is a lack of comparative studies of ABR latency, amplitude, and thresholds obtained from these systems for both traditional and chirp stimuli. Research Design: Repeated measure design. Study Sample: Fifteen adults whose hearing thresholds were ≤25 dB HL participated in this study. Data Collection and Analysis: The Interacoustics Eclipse-25 (EP-25), the Intelligent Hearing System (IHS), and the Vivosonic Integrity V500 systems were used. Peak-to-peak voltage was examined for traditional and chirp stimuli across all three systems. Behavioral and ABR thresholds were obtained for all stimuli. Also, peak V latencies and peak-to-peak amplitudes for all stimuli recorded at 80 dBnHL were examined. Results: Peak-to-peak voltage differed between systems, especially for chirp stimuli. The EP-25 and the IHS systems showed significantly lower behavioral thresholds for some chirp stimuli compared with traditional, comparable stimuli, whereas the Integrity V500 system showed significantly lower behavioral thresholds for broadband click and 4-kHz tone burst stimuli compared with comparable chirp stimuli. Significant differences in behavioral thresholds between systems were observed. The EP-25 (broadband chirp, 1-, 2-, and 4-kHz narrowband chirp) and the IHS (2-kHz narrowband chirp) showed significantly lower ABR thresholds for comparable stimuli, whereas the Integrity V500 system showed lower ABR thresholds for broadband click and 0.5-kHz tone burst stimuli compared with comparable chirp stimuli. ABR thresholds for 2-kHz tone burst and 0.5- and 2-kHz narrowband chirp stimuli were significantly different between systems. The peak V latencies of the IHS system were significantly longer for most of the stimuli compared with other systems. The Integrity V500 system showed significantly lower peak-to-peak amplitudes of peak V for most of the stimuli when compared with other systems. Conclusions: The ABR latencies, amplitudes, and thresholds may differ between ABR recording systems, and clinicians should be aware of these differences to avoid misdiagnosis. Clinical Relevance Statement: The differences in ABR latencies, amplitudes, and thresholds between systems may lead to inconsistencies in diagnostic accuracy. Audiologists should use system-specific normative data.

Indexed as

Acoustic StimulationAuditory ThresholdEvoked Potentials, Auditory, Brain StemAdultAuditory AcuityFemaleHumansMaleMiddle AgedReaction TimeYoung AdultABRauditory brainstem responseIntelligent Hearing SystemInteracoustics EP-25system comparisonVivosonic Integrity V500

Identifiers

PMID42740726
PMCPMC13100346

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.