Evidence map›Paper›PMID 42740026›Full record

ArticleSensors (Basel, Switzerland)2026

Material Detection and Sizing of Sub-Resonant Particles by mm-Wave Far-Field Scattering Measurements Using Orthomode Diplexers.

Max Lippoldt, Jan Hesselbarth

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Max LippoldtInstitute for Radio Frequency Technology (IHF), University of Stuttgart, 70569 Stuttgart, Germany.ORCID 0000-0002-2239-8350
Jan HesselbarthInstitute for Radio Frequency Technology (IHF), University of Stuttgart, 70569 Stuttgart, Germany.ORCID 0000-0002-4905-8591

Funding

Deutsche Forschungsgemeinschaft HE6429/22
6 · The paper itself

Abstract

Bi-static measurements of the scattering of sub-resonant, sub-wavelength-sized spheres and water drops at millimeter-wave frequencies are applied for simultaneous material classification and size estimation. Measurements at Ka-band (26.5-40 GHz) and W-band (75-110 GHz) frequencies are presented that reliably detect the correct material and size of the samples under test. In comparison to traditional resonance-based methods, the sub-resonant approach used here advantageously allows us to characterize smaller particles at a given frequency or to reduce the operating frequency for a given particle size. For the dual-polarized scattering measurements, a novel component (a resonant orthomode diplexer) is proposed. A multi-static measurement is used to additionally determine the position of the sample in the scattering plane. This allows for accurate material classification and size estimation even for a displaced particle. Dielectric and metal spheres with a diameter of 0.4-2 mm are investigated as well as water drops with a volume of 0.5-4 µL.

Indexed as

electromagnetic scatteringinverse scatteringMie theorymillimeter wave

Identifiers

PMID42740026
PMCPMC13568124

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.