Evidence map›Paper›PMID 42739991›Full record

ArticleSensors (Basel, Switzerland)2026

Development of a Low-Cost Portable Exhaled Breath Ammonia Detector for Supplementary Five-Stage CKD Classification Using Embedded Threshold Logic.

Winda Astuti, Juan Alexander Kwan, Elioenai Sitepu, Syauqi Abdurrahman Abrori, Feri Setiawan

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Winda AstutiAutomotive and Robotics Program, Computer Engineering Department, BINUS ASO School of Engineering, Bina Nusantara University, Jakarta 11480, Indonesia.
Juan Alexander KwanAutomotive and Robotics Program, Computer Engineering Department, BINUS ASO School of Engineering, Bina Nusantara University, Jakarta 11480, Indonesia.
Elioenai SitepuIndustrial Engineering Department, Graduate Program, Master of Industrial Engineering, Bina Nusantara University, Jakarta 11480, Indonesia.
Syauqi Abdurrahman AbroriAutomotive and Robotics Program, Computer Engineering Department, BINUS ASO School of Engineering, Bina Nusantara University, Jakarta 11480, Indonesia.ORCID 0000-0003-0217-6301
Feri SetiawanComputer Science Department, Bina Nusantara University, Jakarta 11480, Indonesia.ORCID 0000-0002-4052-674X

Funding

This work is supported by Bina Nusantara University as part of the BHE Initiative Projects 2026 PI2026009
6 · The paper itself

Abstract

Conventional diagnosis of chronic kidney disease (CKD) relies predominantly on invasive blood-based examinations, limiting the scalability of kidney health screening in resource-constrained environments. This study presents embedded engineering framework for non-invasive, breath-based CKD staging framework supported by machine learning and implemented on a low-cost embedded platform. To account for physiological sex differences in baseline creatinine production, estimated glomerular filtration rate (eGFR) values and breath ammonia concentrations were derived from two independent clinical cohorts using sex-specific MDRD equations (incorporating the standard male formula and the 0.742 female correction factor, respectively) and creatinine-BUN conversion models, with male- and female-parameterized algorithms developed in parallel. The resulting feature space was analyzed using four unsupervised clustering approaches to stratify subjects into five clinically meaningful kidney function stages. Stage-specific ammonia thresholds were implemented within an Arduino Nano-based prototype equipped with an MQ-137 gas sensor and OLED display, enabling real-time point-of-care classification. Dataset-level classification accuracy reached 82% for the male algorithm and 92% for the female algorithm. Hospital-based validation on 29 patients (22 male, 7 female) yielded a real-world testing accuracy of 90.5% (20/22) for male patients and 71.4% (5/7) for female patients, a discrepancy largely attributable to the small female sample size. Because the current evaluation lacks healthy control subjects and is constrained by sample size, these empirical results serve primarily to demonstrate hardware-software functional integration and real-world deployment feasibility rather than definitive clinical efficacy. Despite these preliminary, sample-limited clinical datasets, results suggest this approach holds promise as an accessible, non-invasive screening complement to conventional diagnostic pathways, particularly in low-resource healthcare settings.

Indexed as

AmmoniaRenal Insufficiency, ChronicAlgorithmsBreath TestsCreatinineFemaleGlomerular Filtration RateHumansMaleAmmoniaCreatininebreath ammoniachronic kidney diseaseCKD stagingeGFRembedded systemmachine learningMDRDMQ-137non-invasive diagnosispoint-of-caresex-specific algorithm

Identifiers

PMID42739991
PMCPMC13568040

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.