Evidence map›Paper›PMID 42738620›Full record

ArticleMolecules (Basel, Switzerland)2026

Three-Dimensional Titanium Substrates with Anodic TiO

Małgorzata Fus, Jakub Skibiński, Agnieszka Chmielewska-Wysocka, Wojciech Święszkowski, Grzegorz Dariusz Sulka, Magdalena Jarosz

Abstract read
In one paragraph

Article in Molecules (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Małgorzata FusDepartment of Physical Chemistry & Electrochemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Krakow, Poland.ORCID 0009-0002-4896-7950
Jakub SkibińskiInstitute of Heat Engineering, Faculty of Power and Aeronautical Engineering, Warsaw University of Technology, Nowowiejska 21/25, 00-665 Warsaw, Poland.ORCID 0000-0002-5469-6854
Agnieszka Chmielewska-WysockaMultidisciplinary Research Center, Cardinal Stefan Wyszynski University in Warsaw, Marii Konopnickiej 1, 05-092 Dziekanow Lesny, Poland.
Wojciech ŚwięszkowskiMaterials Design Division, Faculty of Materials Science and Engineering, Warsaw University of Technology, Woloska 141, 02-507 Warsaw, Poland.
Grzegorz Dariusz SulkaDepartment of Physical Chemistry & Electrochemistry, Faculty of Chemistry, Jagiellonian University, Gronostajowa 2, 30-387 Krakow, Poland.ORCID 0000-0001-7431-617X
Magdalena JaroszIndependent Researcher, Kazimierza Wielkiego 140, 30-074 Krakow, Poland.

Funding

National Science Centre 2017/25/B/ST8/01599
6 · The paper itself

Abstract

Enhancing the performance of titanium biomaterials remains a critical challenge in the development of durable implant materials, particularly under complex physiological conditions where corrosion processes are influenced by interactions with biological species. Electrochemical oxidation has emerged as a promising approach for generating nanostructured titanium dioxide layers, which can improve corrosion resistance. In this study, nanostructured oxide layers were synthesized on additively manufactured 3D titanium scaffolds via anodization in a fluoride-containing ethylene glycol and water electrolyte. Corrosion resistance was systematically evaluated using open-circuit potential measurements, Tafel analysis, and electrochemical impedance spectroscopy, considering the effects of biological medium composition and prolonged exposure to corrosive conditions. The main scientific contribution of this work is the elucidation of the time-dependent corrosion behavior and electrochemical stability of anodized additively manufactured titanium scaffolds under physiological exposure conditions. The results demonstrated that the medium composition significantly influenced the properties of the anodized materials, primarily due to the adsorption of medium species on the nanostructured surface. Prolonged exposure tests further confirmed the superior durability of the coatings, which is attributed to the formation of a protective protein layer that enhances corrosion resistance in aggressive environments. These findings advance the understanding of time-dependent corrosion behavior in complex biological environments and highlight the effectiveness of nanostructured oxide layers in maintaining the electrochemical stability of titanium biomaterials during prolonged exposure. Combined with additive manufacturing, this approach represents a promising route toward the development of patient-specific implants with enhanced durability and long-term functionality for bone regeneration applications.

Indexed as

Coated Materials, BiocompatibleTitaniumBiocompatible MaterialsCorrosionDielectric SpectroscopyElectrodesMaterials TestingNanostructuresOxidation-ReductionSurface PropertiesBiocompatible MaterialsCoated Materials, BiocompatibleTitaniumtitanium dioxideanodizationbioimplantscorrosion resistanceelectrochemical impedance spectroscopynanostructured titanium dioxide

Identifiers

PMID42738620
PMCPMC13567555

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.