Evidence map›Paper›PMID 42737186›Full record

ArticlePolymers2026

Finite Element Investigation of the Influence of Strut Diameter on the Mechanical Performance of Balloon-Expandable Biodegradable PLA/PDO Coronary Stents.

Elhadj Besseghier, Fatima Zohra Kettaf, Ahmed Ouadah Bouakkaz, Abdelkader Djebli, Ali Benhamena, Dursun Murat Sekban, Ecren Uzun Yaylacı, Merve Terzi, Murat Yaylacı

Abstract read
In one paragraph

Article in Polymers, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Elhadj BesseghierMechanical Engineering Department, Faculty of Technology, Hassiba Benbouali University of Chlef, Hay Salem, National Road N19-02000, Chlef 02000, Algeria.
Fatima Zohra KettafFaculty of Mechanical Engineering, University of Science and Technology of Oran Mohamed-Boudiaf USTO-MB, Oran 31000, Algeria.
Ahmed Ouadah BouakkazMechanical Engineering Department, Faculty of Technology, Hassiba Benbouali University of Chlef, Hay Salem, National Road N19-02000, Chlef 02000, Algeria.ORCID 0000-0002-1430-2144
Abdelkader DjebliMechanics of Materials, Energy and Environment Laboratory (L2M2E), University of Mascara, Mascara 29000, Algeria.ORCID 0000-0001-9102-2202
Ali BenhamenaMechanics of Materials, Energy and Environment Laboratory (L2M2E), University of Mascara, Mascara 29000, Algeria.
Dursun Murat SekbanDepartment of Marine Engineering Operations, Karadeniz Technical University, Trabzon 61080, Türkiye.ORCID 0000-0002-7493-1081
Ecren Uzun YaylacıFaculty of Fisheries, Recep Tayyip Erdogan University, Rize 53100, Türkiye.
Merve TerziDepartment of Civil Engineering, Recep Tayyip Erdogan University, Rize 53100, Türkiye.
Murat YaylacıDepartment of Civil Engineering, Recep Tayyip Erdogan University, Rize 53100, Türkiye.ORCID 0000-0003-0407-1685

Funding

Recep Tayyip Erdoğan University 02026001015041
6 · The paper itself

Abstract

This study numerically investigates the influence of strut diameter on the deployment behavior of a balloon-expandable biodegradable stent with rhombic cell architecture using finite element analysis. The stent material was represented by a 60/40 poly(lactic acid)/polydioxanone (PLA/PDO) blend. Four stent configurations with strut diameters of 0.15, 0.25, 0.35, and 0.50 mm were analyzed under identical deployment conditions. The numerical evaluation considered von Mises stress together with five deployment indicators: diametral strain, elastic recoil, dog-boning, foreshortening, and longitudinal retraction. The results show that increasing the strut diameter reduces elastic recoil, foreshortening, and longitudinal retraction, thereby enhancing post deployment dimensional stability. However, thicker struts also increase the dog-boning effect, indicating less uniform radial expansion. Among the investigated designs, the stent with a 0.35 mm strut diameter showed a balanced response between deployment uniformity and post deployment mechanical stability under the adopted numerical assumptions. For this configuration, elastic recoil, foreshortening, longitudinal retraction, and dog-boning were approximately 6.2%, 10%, 37%, and 8.9%, respectively. These findings provide practical design guidance for biodegradable polymeric vascular stents.

Indexed as

biodegradable stentcoronary stentdeployment behaviorfinite element analysismechanical performancePLA/PDO blendstrut diameter

Identifiers

PMID42737186
PMCPMC13568007

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.