ArticleFacts, views & vision in ObGyn2026
Poor knot security when closing running sutures with three threads.
Article in Facts, views & vision in ObGyn, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Knot security varies with half-knot and half-hitch sequences, rotation sense, and the type and diameter of sutures. Objectives: To evaluate the security of knots with three threads, as used for tying off running sutures. Methods: Three-way randomised experiments, with a factorial design and 10 knots/cell. The first experiment evaluated the knot security of a surgical knot (H2H1sH1s) for single stitches (2 threads) or running sutures (3 threads), using polyglactin 910 or polydioxanone, of 2-0 or 1 diameter. The second experiment evaluated the knot security of a running suture with 4 or 5 half-hitch sequences and 2 or 3 blocking knots, using polyglactin 910 or polydioxanone, and with diameters of 2-0 or 1. Main Outcome Measures: Knot security in Newton, measured with a digital dynamometer. With increasing forces, the knot either slipped open or blocked, causing the suture to break. Results: In the first experiment, the knot security of surgical knots was less with monofilament ( Conclusions: Compared to knots tied with two threads, knots with three threads have a lower and more variable knot security, especially with larger monofilament sutures. What is New?: Knots with 3 threads should be avoided, as they may occasionally open with forces below 30 or 10 Newton.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.