Evidence map›Paper›PMID 42735121›Full record

ArticleIEEE transactions on ultrasonics2026

Rapid, Accurate 3-D Localization of Inertial Cavitation Events Using a Large Aperture, Narrowband, Receive-Capable Focused Ultrasound Array.

Mahmoud Komaiha, Ellen Yeats, Timothy L Hall, Zhen Xu, Jonathan R Sukovich

Abstract read
In one paragraph

Article in IEEE transactions on ultrasonics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Mahmoud Komaiha
Ellen Yeats
Timothy L Hall
Zhen Xu
Jonathan R Sukovich

Funding

Ultrasound-guided Ultra-steerable Histotripsy Array System for Non-invasive treatment of Soft Tissue SarcomaR01EB034399 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Zhen Xu · 2023 to 2026
$2.2M
Acoustic Cavitation Emission (ACE) Feedback Methods for Monitoring Histotripsy-Induced Tissue Fractionation In SituR01EB032772 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI SUKOVICH, JONATHAN ROBERT · 2022 to 2025
$2.0M
Aberration Correction for Histotripsy Ablation of LiverR01CA282200 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Timothy L Hall · 2024 to 2026
$1.7M
Transcranial MRI- and Ultrasound- guided histotripsy (tcMR-USgHt) systemR01EB037129 · NIBIB · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Zhen Xu · 2025 to 2026
$1.2M
NCI NIH HHS R01 CA282200NIBIB NIH HHS R01 EB032772NIBIB NIH HHS R01 EB034399NIBIB NIH HHS R01 EB037129
6 · The paper itself

Abstract

Accurate, real-time localization of cavitation events is critical for ensuring the safety and efficacy of histotripsy treatments. Current methods, such as 2-D passive acoustic mapping (PAM) and B-mode imaging, lack the necessary speed and spatial resolution for the high-treatment rates (> 100 Hz) of histotripsy. In this study, we present two computationally efficient, time-domain methods-trilateration acoustic cavitation emission (TRACE) and bandwidth-limited, large-aperture, active-acoustic, and spatio-temporal mapping (BLAST)-for rapid 3-D cavitation localization using a large-aperture, narrowband, and receive-capable focused ultrasound (US) array. TRACE estimates cavitation locations by measuring time-of-arrival (TOA) differences of cavitation collapse's shockwave emissions across an array, enabling direct localization with minimal computation. BLAST, a modified version of PAM, actively detects and time-windows collapse shockwave signals to improve processing efficiency. Experimental validation using synchronized optical imaging demonstrated submillimeter cavitation localization accuracy for both methods. TRACE achieved localization rates $\ge 100$ Hz with a computation time of 7 ms per pulse, while BLAST achieved rates exceeding 60 Hz. Results also confirmed a prefocal shift in cavitation center-of-mass relative to the array's geometric focus, highlighting the effect of focal pressure on bubble cloud dynamics. These findings suggest that TRACE and BLAST provide viable solutions for real-time 3-D cavitation monitoring, improving the precision and control of histotripsy treatments.

Indexed as

High-Intensity Focused Ultrasound AblationImaging, Three-DimensionalEquipment DesignPhantoms, Imaging

Identifiers

PMID42735121
PMCPMC13576058

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.