Evidence map›Paper›PMID 42734919›Full record

Trial reportJAMA network open2026

Neonatal Ventilation Training Using a Low-Cost, High-Fidelity Simulator in a Low-Resource Setting: A Randomized Clinical Trial.

Davide Mocellin, Sabina Maglio, Mary-Winnie Nanyaro, Paolo Belardi, Martina Borellini, Elizabeth H Shayo, Amerigo Ferrari, Benjamin Mfaume, Nyanda Ntinginya, Selene Tognarelli and 1 more

Registry-linked trialAbstract readRandomized Controlled Trial
In one paragraph

Trial report in JAMA network open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07665164 (Experimental Study and Training for Tanzanian Students and Health Professionals With a New Simulator for Manual Neonatal Ventilation), which is not on this map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT07665164 nacompletednot on this map

Experimental Study and Training for Tanzanian Students and Health Professionals With a New Simulator for Manual Neonatal Ventilation

TypeinterventionalSponsorScuola Superiore di Studi Universitari e di Perfezionamento Sant'AnnaRan2025 to 2025Enrolled79ConditionsTeaching Manual Neonatal VentilationArmsTraining
3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Davide MocellinThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.
Sabina MaglioThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.
Mary-Winnie NanyaroNational Institute for Medical Research, Dar es Salaam, Tanzania.
Paolo BelardiDoctors with Africa CUAMM, Iringa, Tanzania.
Martina BorelliniDoctors with Africa CUAMM, Iringa, Tanzania.
Elizabeth H ShayoNational Institute for Medical Research, Dar es Salaam, Tanzania.
Amerigo FerrariDivision of Obstetrics and Gynecology, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy.
Benjamin MfaumeTosamaganga Regional Referral Hospital, Iringa, Tanzania.
Nyanda NtinginyaNational Institute for Medical Research, Dar es Salaam, Tanzania.
Selene TognarelliThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.
Arianna MenciassiThe BioRobotics Institute, Scuola Superiore Sant'Anna, Pisa, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Importance: Neonatal mortality rates in sub-Saharan Africa remain high (26 per 1000 live births). Limited access to advanced respiratory support and shortage of trained health personnel make manual ventilation a lifesaving, yet high-risk, essential competence. Simulation-based training may strengthen neonatal ventilation skills, but evidence on acceptability and educational effectiveness of low-cost, high-fidelity simulators in resource-limited settings is limited. Objective: To build local capacity in manual neonatal ventilation and to assess acceptability and educational effectiveness of different simulator configurations across participants with varying levels of clinical experience. Design, Setting, and Participants: This randomized clinical trial was conducted from June 17 to 20, 2025, at a regional-level referral hospital in Tanzania. Participants included undergraduate medical students with no prior neonatal ventilation experience and local health professionals. Interventions: Participants were randomly assigned to 1 of 3 simulator configurations (medium-fidelity passive setup with no feedback, high-fidelity passive setup with mechanical feedback, and high-fidelity active setup with mechanical and sensors feedback). All participants received a 4-day training program consisting of theoretical lectures, hands-on simulation training with 1 of the 3 simulator configurations, and a standardized final evaluation. Main Outcomes and Measures: The primary outcome was objective ventilatory performance measured by the simulator during the hands-on sessions, defined as ventilation frequency and peak inspiratory pressure (PIP). Secondary outcomes included tutor-based performance evaluation, theoretical knowledge assessment in a 10-item questionnaire, and practical ventilation performance evaluation in a 12-item checklist. Tertiary outcomes were user-reported acceptability, perceived usefulness, perceived ease of use, behavioral intention, and simulator fidelity, assessed using the Technology Acceptance Model (TAM). Results: Both students (42 participants; median [IQR] age, 21 [20-22] years; 25 female [59.5%]) and health professionals (37 participants; median [IQR] age, 26 [23-29] years; 30 female [81.1%]) demonstrated improvements in theoretical knowledge (posttraining vs pretraining mean [SE] score [maximum 10 points]: students, 8.88 [0.13] vs 8.29 [0.17]; P < .001; health professionals, 9.14 [0.13] vs 8.65 [0.17]; P = .03) and practical ventilation performance following training (mean [SD] evaluation score [maximum 12 points]: students, 10.4 [0.7]; health professionals, 10.2 [0.9]). Training effectiveness varied by simulator configuration and participant experience. Among students, a medium-fidelity configuration was associated with improved ventilation frequency and PIP, whereas among health professionals, an active high-fidelity configuration supported improved performance during hands-on training. TAM scores confirmed a high simulator acceptability with no differences between groups. Conclusions and Relevance: In this randomized clinical trial of an adaptable, low-cost, high-fidelity neonatal ventilation simulator, effective training across heterogeneous learner groups in a resource-limited setting was supported; tailoring simulator feedback to learners' baseline experience enhanced training effectiveness. These findings support the feasibility of scalable, simulation-based neonatal ventilation training in low-resource environments. Further research on skill retention, transfer to clinical practice, and neonatal outcomes are needed. Trial Registration: ClinicalTrials.gov Identifier: NCT07665164.

Indexed as

High Fidelity Simulation TrainingRespiration, ArtificialSimulation TrainingAdultClinical CompetenceFemaleHumansInfant, NewbornMaleResource-Limited SettingsTanzania

Identifiers

PMID42734919
PMCPMC13576422

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.