Evidence map›Paper›PMID 42732005›Full record

ArticleNature communications2026

Robust biexciton preparation for entangled photon-pair generation by single-shot Floquet driving.

Jun-Yong Yan, Paul C A Hagen, Hang-Yu Ge, Fang-Yuan Li, Hans-Georg Babin, Wei E I Sha, Bo Wang, Zhi-Hua Gan, Andreas D Wieck, Arne Ludwig and 5 more

Abstract read
In one paragraph

Article in Nature communications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors.

Jun-Yong Yan *State Key Laboratory of Extreme Photonics and Instrumentation, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, China.ORCID http://orcid.org/0000-0001-5624-2322
Paul C A Hagen *Theoretische Physik III, Universität Bayreuth, Bayreuth, Germany.ORCID http://orcid.org/0009-0003-9669-9097
Hang-Yu GeState Key Laboratory of Extreme Photonics and Instrumentation, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, China.
Fang-Yuan LiState Key Laboratory of Extreme Photonics and Instrumentation, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, China.
Hans-Georg BabinExperimental Physics VI, Ruhr University Bochum, Bochum, Germany.
Wei E I ShaState Key Laboratory of Extreme Photonics and Instrumentation, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, China.ORCID http://orcid.org/0000-0002-7431-8121
Bo WangCryogenic Center, Hangzhou City University, Hangzhou, China.
Zhi-Hua GanZhejiang Key Laboratory of Refrigeration and Cryogenic Technology, Zhejiang University, Hangzhou, China.
Andreas D WieckExperimental Physics VI, Ruhr University Bochum, Bochum, Germany.ORCID http://orcid.org/0000-0001-9776-2922
Arne LudwigExperimental Physics VI, Ruhr University Bochum, Bochum, Germany.ORCID http://orcid.org/0000-0002-2871-7789
Chao-Yuan JinZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, China.ORCID http://orcid.org/0009-0005-9753-4950
Vollrath M AxtTheoretische Physik III, Universität Bayreuth, Bayreuth, Germany.ORCID http://orcid.org/0009-0003-8462-1372
Da-Wei WangZhejiang Key Laboratory of Micro-Nano Quantum Chips and Quantum Control, School of Physics, Zhejiang University, Hangzhou, China.ORCID http://orcid.org/0000-0003-3336-8568
Moritz CygorekCondensed Matter Theory, Department of Physics, TU Dortmund, Dortmund, Germany. moritz.cygorek@tu-dortmund.de.ORCID http://orcid.org/0000-0003-4406-851X
Feng LiuState Key Laboratory of Extreme Photonics and Instrumentation, College of Information Science and Electronic Engineering, Zhejiang University, Hangzhou, China. feng_liu@zju.edu.cn.ORCID http://orcid.org/0000-0002-2082-7561

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Quantum emitters driven by resonant two-photon excitation are a leading source for deterministically generated entangled photon pairs, essential for scalable photonic quantum technologies. However, conventional excitation schemes pose various constraints, limiting their scalability and practicability. Here, we demonstrate how biexciton preparation schemes with significantly improved robustness and reduced experimental demands can be identified using a novel design principle: ultrafast single-shot Floquet driving. This is achieved by employing two strongly and symmetrically detuned pulses, whose superposition generates a stroboscopic Hamiltonian that enables direct coupling between ground and biexciton states. Moreover, a pulse delay serves as a tuning knob, introducing an effective magnetic field making biexciton preparation particularly robust. Experimentally, we achieve a biexciton occupation exceeding 96% and preserve photon-pair entanglement with a fidelity of 93.4%. Our work opens avenues for the design of quantum control protocols with superior performance across diverse quantum emitters and qubit platforms.

Identifiers

PMID42732005
PMCPMC13570888

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.