Evidence map›Paper›PMID 42730942›Full record

ArticleBiomechanics and modeling in mechanobiology2026

Combined cartilage thickness and mechanical property mismatch drives local strain amplification at the patellar osteochondral allograft interface.

Michael A Hernández Lamberty, John A Grant, Ellen M Arruda, Rhima M Coleman

Abstract read
In one paragraph

Article in Biomechanics and modeling in mechanobiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Michael A Hernández LambertyDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA.ORCID http://orcid.org/0000-0001-8335-3060
John A GrantDepartment of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI, USA.ORCID http://orcid.org/0000-0003-4885-5596
Ellen M ArrudaDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA.ORCID http://orcid.org/0000-0002-8827-9426
Rhima M ColemanDepartment of Mechanical Engineering, University of Michigan, Ann Arbor, MI, USA. rhimacol@umich.edu.ORCID http://orcid.org/0000-0003-2954-0708

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Patellar osteochondral allograft (OCA) transplantation treats focal cartilage defects, but donor-recipient cartilage thickness and mechanical compatibility are not routinely quantified during graft selection. This idealized computational study evaluated associations of donor-to-recipient (D/R) thickness ratio, absolute stiffness, stiffness contrast, and depth-dependent stiffness with interface-local strain. Two-dimensional axisymmetric finite element models were subjected to a spatially uniform nominal pressure of 1.00 MPa. Nine D/R ratios (0.33-3.25) and eleven homogeneous donor/recipient (DC/RC) Young's modulus combinations (2.50-7.00 MPa) yielded 99 homogeneous cases; nine functionally graded material (FGM) cases were evaluated. Primary outcomes were 95th percentile (P95) values of the nodewise compressive strain magnitude and tensor maximum shear strain within a fixed 0.25-mm local interface region of interest (ROI). This robust upper-tail measure is less sensitive than a single nodal maximum. In the matched homogeneous control, P95 values were 0.031 and 0.015. The largest homogeneous values were 0.412 and 0.347 at D/R=3.25 and DC/RC=7.0/2.5 MPa. Same-side concentration factors normalized local P95 to median strain in the same model's 0.75-1.00 mm far-field band. Pooled factors were 3.71 ± 2.04 for compression and 6.03 ± 3.79 for maximum shear in homogeneous cases (n = 198 model-sides), and 3.51 ± 2.17 and 5.69 ± 4.03 in FGM cases (n = 18). FGM values were lower than both extreme homogeneous mismatch references at every D/R ratio. Across formulations, thickness disparity remained associated with interface-local upper-tail strain. These results support evaluating donor-recipient cartilage thickness and material compatibility alongside surface congruity and osseous integration in future experimental and patient-specific modeling studies.

Indexed as

AllograftsCartilageCartilage, ArticularPatellaStress, MechanicalBiomechanical PhenomenaCompressive StrengthComputer SimulationElastic ModulusFinite Element AnalysisHumansModels, BiologicalCartilageFinite element analysisOsteochondral allograft transplantPatellaPatellofemoral joint

Identifiers

PMID42730942
PMCPMC13570921

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked