ArticleFrontiers in medicine2026
Real-time vascular monitoring of PDLs and IPL for vascular treatment: effects of fluence and pulse duration on a rabbit ear model.
Article in Frontiers in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Pulsed dye lasers (PDLs) and intense pulsed light (IPL) are commonly used for treating cutaneous vascular diseases but lack standardized and reproducible treatment protocols. Reliable vascular models are needed to visually assess posttreatment responses. Methods: Sixteen male rabbits were divided into two groups, with each ear subdivided into three treatment regions. PDL treatment was applied with pulse durations of 0.45 ms (fluences: 4, 5.5, and 8 J/cm Results: The dorsal ear vessels of rabbits consisted of longitudinally arranged main blood vessels (MBVs) and fan-shaped branch blood vessels (BBVs), with diameters ranging from 150-300 μm and 90-120 μm, respectively. In the PDL treatment, effective vessel closure with limited peripheral tissue damage was achieved using 0.45 ms at 5.5 J/cm Conclusion: The rabbit ear vascular model, combined with dermoscopy, LSCI, and histopathology, provides a reproducible multimodal platform for longitudinal evaluation and systematic parameter screening, offering a reliable preclinical foundation for comparative assessment and protocol refinement prior to clinical translation.