Evidence map›Paper›PMID 42728508›Full record

ArticleMikrochimica acta2026

Efficient fabrication of paper-based microfluidic biosensors incorporating laser-induced graphene for label-free electrochemical immunoassays.

Yuxin Pan, Jiayin Chi, Yuyang Gu, Erzhen Chen, Xiao Li, Huan Liu, Dichen Li

Abstract read
PubMed Publisher
In one paragraph

Article in Mikrochimica acta, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yuxin PanState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China.ORCID http://orcid.org/0009-0003-4047-1077
Jiayin ChiState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China.ORCID http://orcid.org/0009-0007-9588-9808
Yuyang GuState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China.ORCID http://orcid.org/0009-0001-5777-5232
Erzhen ChenShanghai Institute of Aviation Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.ORCID http://orcid.org/0000-0001-7835-6080
Xiao LiState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China. xiao.li@xjtu.edu.cn.ORCID https://orcid.org/0000-0002-1200-8590
Huan LiuShanghai Institute of Aviation Medicine, Ruijin Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China. huanliu150808@sjtu.edu.cn.ORCID http://orcid.org/0009-0005-6103-2115
Dichen LiState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, Shaanxi, 710049, China.ORCID http://orcid.org/0009-0006-2257-6109

Funding

Key Research and Development Projects of Shaanxi Province 2024SF-ZDCYL-04-11National Natural Science Foundation of China 52105588
6 · The paper itself

Abstract

To improve the performance in electrochemical immunoassays, paper-based devices typically necessitate the introduction of transducing materials through additional preparation steps, and the assay procedures often require labeling steps. Here we show that laser fabrication can generate both transducing and microfluidic components of paper-based devices to support label-free immunoassays. Laser parameters were adjusted to improve the electrochemical properties of paper-based graphenic transducing structures. Surface treatment for label-free biosensing was performed, and the device configuration and operation for electrochemical impedance spectroscopy sensing were explored. Interleukin-6 protein was used as a representative target to evaluate the analytical performance of the developed immunosensors. In phosphate buffered saline, the immunosensors exhibited a sensitivity of 67.95 Ω/decade and a limit of detection of 4.66 pg/mL. In artificial serum, the immunosensors exhibited a sensitivity of 57.08 Ω/decade and a limit of detection of 5.35 pg/mL. The clinical application potential was further demonstrated with human serum samples. The presented approach for developing paper-based microfluidic immunosensors can enhance their performance while maintaining ease of fabrication and usage to meet different requirements in clinical practice.