Evidence map›Paper›PMID 42726463›Full record

ArticleLa Radiologia medica2026

Artificial intelligence-assisted triage of screening mammograms following breast-conserving therapy: a comparative simulation study.

Ga Eun Park, Bong Joo Kang, Sung Hun Kim, Han Song Mun

Abstract read
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Ga Eun ParkDepartment of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Banpo-Daero 222, Seocho-Gu, Seoul, 06591, Republic of Korea.
Bong Joo KangDepartment of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Banpo-Daero 222, Seocho-Gu, Seoul, 06591, Republic of Korea. lionmain@catholic.ac.kr.ORCID http://orcid.org/0000-0002-5991-6035
Sung Hun KimDepartment of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Banpo-Daero 222, Seocho-Gu, Seoul, 06591, Republic of Korea.
Han Song MunDepartment of Radiology, College of Medicine, Seoul St. Mary's Hospital, The Catholic University of Korea, Banpo-Daero 222, Seocho-Gu, Seoul, 06591, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo evaluate the diagnostic performance and potential of artificial intelligence (AI)-based triage for screening mammograms following breast-conserving therapy (BCT). METHODS AND MATERIALS: In this retrospective study, consecutive post-BCT mammograms obtained between January and May 2021 were analyzed and divided into ipsilateral and contralateral breasts. Triage was simulated using three models with a commercial AI-based computer-aided detection (CAD), and outcomes were categorized as recall or no recall: (1) original report-based triage, (2) standalone AI, and (3) decision referral AI-triage. Cancer detection rate (CDR), recall rates, and diagnostic performance were evaluated.

resultsA total of 1190 women were enrolled. For the ipsilateral breast, 10 mammography-visible recurrences were identified. All three models-original report, standalone AI, and decision referral AI-achieved equivalent CDR (6.6 per 1000) and sensitivity (80%), with recall rates of 3.4%, 23.0%, and 2.8%, respectively. AI-CAD classified 77% of examinations as negative without a reduction in CDR or sensitivity. For the contralateral breast, three recurrences were identified. The original report yielded a CDR of 1.8 per 1000, a recall rate of 1.9%, and 66.7% sensitivity. While AI-CAD triaged 90% of examinations as negative, standalone AI achieved a CDR of 2.6 per 1000, recall rate of 9.8%, and 100% sensitivity. Decision referral AI maintained CDR and sensitivity with a lower recall rate (2.0%).

conclusionsOur simulation suggests that AI-based triage can exclude a substantial portion of negative mammograms following BCT without a reduction in CDR or sensitivity. Nonetheless, radiologist expertise remains crucial, particularly in interpreting the ipsilateral breast, given the higher false positive rate of AI-CAD.

Indexed as

Artificial intelligenceBreast cancerMammographyPost-surgery surveillance

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.