Evidence map›Paper›PMID 42726441›Full record

ArticleRadiological physics and technology2026

Injection pressure in contrast-enhanced computed tomography is influenced by catheter size, contrast medium type, and injection rate.

Nobutada Suzuki, Takayuki Sakai, Eiichiro Okumura, Hajime Ito, Shigehiro Ochi, Noriyuki Yanagawa, Takahisa Sasho

Abstract read
PubMed Publisher
In one paragraph

Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Nobutada SuzukiDepartment of Radiology, Eastern Chiba Medical Center, 3-6-1 Okayamadai, Togane, 283-8686, Chiba, Japan. n-suzuki@tkmedical.jp.ORCID http://orcid.org/0000-0003-2641-7042
Takayuki SakaiDepartment of Radiological Technology, Faculty of Health Sciences, Tsukuba International University, 6-20-1, Manabe, Tsuchiura, 300-0051, Ibaraki, Japan.
Eiichiro OkumuraDepartment of Radiological Technology, Faculty of Health Sciences, Tsukuba International University, 6-20-1, Manabe, Tsuchiura, 300-0051, Ibaraki, Japan.
Hajime ItoDepartment of Radiology, Eastern Chiba Medical Center, 3-6-1 Okayamadai, Togane, 283-8686, Chiba, Japan.
Shigehiro OchiDepartment of Radiology, Eastern Chiba Medical Center, 3-6-1 Okayamadai, Togane, 283-8686, Chiba, Japan.
Noriyuki YanagawaDepartment of Radiological Technology, Faculty of Health Sciences, Tsukuba International University, 6-20-1, Manabe, Tsuchiura, 300-0051, Ibaraki, Japan.
Takahisa SashoDivision of Musculoskeletal Pain and Diseases, Center for Preventive Medical Sciences, Chiba University, 1-8-1 Inohana, Chuo-ku, Chiba, 260-8670, Chiba, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Maintaining stable injection pressure is essential for safe and effective contrast-enhanced computed tomography (CE-CT), but the combined effects of procedural factors on maximum injection pressure remain unclear. This retrospective study analyzed 4223 CE-CT examinations performed between April 2022 and March 2025 using data automatically recorded by an integrated CE-evidence system. A general linear model was used to evaluate the effects of IV catheter size (20G or 22G), injection rate (2.5, 3.0, or 3.5 mL/s), and contrast medium (CM) type on maximum injection pressure after adjustment for age, sex, and body mass index. IV catheter size had the greatest effect on maximum injection pressure (partial η² = 0.247, p < 0.001), with significantly higher pressures for 22G than for 20G catheters. CM type (partial η² = 0.159, p < 0.001) and injection rate (partial η² = 0.075, p < 0.001) were also significant independent factors. Significant two-way interactions were observed between IV catheter size and injection rate, IV catheter size and CM type, and injection rate and CM type (all p < 0.001), whereas the three-way interaction was not significant (p = 0.129). Adjusted estimated marginal means showed that the increase in maximum injection pressure with higher injection rates was greater for 22G than for 20G catheters. These findings indicate that maximum injection pressure is determined by both individual procedural factors and their interactions, and that optimizing combinations of IV catheter size, CM type, and injection rate may help reduce excessive injection pressure in clinical practice.

Indexed as

CE-evidence systemContrast-enhanced computed tomography (CT)Contrast mediumInjection pressureRadiology information system (RIS)

Identifiers

PMID42726441

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.