Evidence map›Paper›PMID 42726303›Full record

ArticleLasers in medical science2026

Ionic characteristics and osmolarity of cooling fluid in hepatic laser ablation: a 7T MRI-based comparison in ex vivo bovine liver.

Fiona Mankertz, Josephine Berger, Nour Maalouf, Benedikt Stenzl, Antonia Ashkar, Ole Gemeinhardt, Johannes Uhlig, Saif Afat, Norbert Hosten, Judith Herrmann

Abstract readComparative Study
In one paragraph

Article in Lasers in medical science, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Fiona MankertzDepartment of Diagnostic and Interventional Radiology, Universitätsklinikum Tübingen, Tübingen, Germany. fiona.mankertz@med.uni-tuebingen.de.ORCID https://orcid.org/0000-0002-7441-1406
Josephine BergerDepartment of Diagnostic and Interventional Radiology, Universitätsklinikum Tübingen, Tübingen, Germany.
Nour MaaloufDepartment of Diagnostic and Interventional Radiology, Universitätsklinikum Tübingen, Tübingen, Germany.
Benedikt StenzlDepartment of Diagnostic and Interventional Radiology, Universitätsklinikum Tübingen, Tübingen, Germany.
Antonia AshkarDepartment of Diagnostic and Interventional Radiology, Universitätsklinikum Tübingen, Tübingen, Germany.
Ole GemeinhardtDepartment of General and Visceral Surgery, Charité - University Medicine Berlin, Berlin, Germany.
Johannes UhligDepartment of Diagnostic and Interventional Radiology, Universitätsklinikum Tübingen, Tübingen, Germany.
Saif AfatDepartment of Diagnostic and Interventional Radiology, Universitätsklinikum Tübingen, Tübingen, Germany.
Norbert HostenInstitute for Diagnostic Radiology and Neuroradiology, Greifswald University Hospital, Greifswald, Germany.
Judith HerrmannDepartment of Diagnostic and Interventional Radiology, Universitätsklinikum Tübingen, Tübingen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To compare MRI-defined ablation volume among three cooling fluids with different ionic characteristics and osmolarity in ex vivo bovine liver tissue. In this ex vivo pilot study, 36 laser ablations were performed in five bovine livers using internal applicator cooling with 0.9% sodium chloride, 5% dextrose in water, or 10% mannitol at 60 mL/h. Post-ablation MRI was performed at 7 T. Primary endpoint was manual MRI volumetry; secondary endpoint was maximum axial diameter. Semi-automatic volumetry and intra-rater repeatability were assessed as supplementary analyses. Linear mixed-effects models with source liver as a random intercept were used for group comparisons. Overall, 33/36 ablations were evaluable. Mean ablation volume was 21.4 ± 1.5 cm³ with sodium chloride, 21.7 ± 1.4 cm³ with dextrose, and 23.6 ± 1.3 cm³ with mannitol. Cooling fluid group was associated with ablation volume (p = 0.002). Ablation volume was larger with mannitol than with sodium chloride (mean difference, 2.2 cm³; adjusted p < 0.001) or 5% dextrose (mean difference, 1.9 cm³; adjusted p = 0.006). Maximum axial diameter showed the same group pattern. Agreement between manual and semi-automatic volumetry was high (ICC, 0.96); intra-rater repeatability was excellent for volume (ICC, 0.98) and diameter (ICC, 0.97). In ex vivo bovine liver, 10% mannitol was associated with larger MRI-defined laser ablation volumes than 0.9% sodium chloride or 5% dextrose.

Indexed as

Laser TherapyLiverAnimalsCattleGlucoseIn Vitro TechniquesMagnetic Resonance ImagingMannitolOsmolar ConcentrationPilot ProjectsSodium ChlorideGlucoseMannitolSodium ChlorideAblation volumeCooling fluidEx vivo bovine liver modelHepatic ablationLaser ablationMRI volumetry

Identifiers

PMID42726303
PMCPMC13569545

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.