Evidence map›Paper›PMID 42725003›Full record

ArticleGland surgery2026

Evaluation of the efficacy and safety of breast augmentation using implants combined with autologous fat grafting: a retrospective study of 219 cases.

Phung Van Nguyen, Van Thanh Nguyen

Abstract read
In one paragraph

Article in Gland surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Phung Van NguyenSchool of Medicine and Pharmacy, Tra Vinh University, Hoa Thuan Ward, Vietnam.ORCID https://orcid.org/0009-0006-8712-5202
Van Thanh NguyenSchool of Medicine and Pharmacy, Tra Vinh University, Hoa Thuan Ward, Vietnam.ORCID https://orcid.org/0000-0002-4310-9191

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Hybrid breast augmentation-silicone gel implant placement combined with autologous fat grafting-is increasingly used in women with a thin soft-tissue envelope, yet large series from centers outside the groups that first described the technique remain limited. We evaluated the volumetric efficacy, safety, and aesthetic outcomes of hybrid augmentation, and examined whether the size gain explained patient-reported satisfaction. Methods: We retrospectively reviewed 219 women who underwent primary hybrid breast augmentation, with complete 12-month follow-up. Outcomes were the change in breast circumference, patient-reported satisfaction (BREAST-Q Augmentation module, version 2.0; Satisfaction with Breasts domain, scored 0-100), a surgeon-rated aesthetic score, and postoperative complications. Data were analyzed in SPSS version 26.0 using paired t-tests, Fisher's exact test, univariate logistic regression, and Pearson correlation. Results: Breast circumference increased by a mean of 12.6±1.3 cm at 6 months and remained augmented at 12 months (mean gain 10.3±2.5 cm; both P<0.001). BREAST-Q satisfaction rose from a preoperative baseline of 54.4±5.9 to 80.9±5.7 at 6 months and 82.2±5.4 at 12 months (mean improvement +27.8 at 12 months; 95% confidence interval: 26.9-28.8; P<0.001), and surgeon aesthetic scores were consistently high. The overall complication rate was low (5.9%; 13/219); all events were minor, and no Baker grade IV capsular contracture occurred. Patient satisfaction was not explained by the magnitude of the size gain: BREAST-Q was not associated with the increase in circumference at either time point (r=0.05 at 6 months and r=0.06 at 12 months; both P>0.3). No complication occurred among the 33 patients with a smoking history (P=0.23), and body mass index (BMI) was not associated with complications (odds ratio 1.02; P=0.92). Conclusions: Hybrid breast augmentation provided substantial and durable enlargement with a low, exclusively minor complication profile in thin-tissue patients. Because satisfaction was largely independent of the degree of size increase, these findings support prioritizing soft-tissue quality and natural contour over volume alone. In the absence of an implant-only comparison group, these findings characterize outcomes after hybrid augmentation rather than establishing its superiority or the independent contribution of fat grafting.

Indexed as

augmentation complicationsautologous fat graftingBREAST-QImplant-based breast augmentationpatient satisfaction

Identifiers

PMID42725003
PMCPMC13561599

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.