Evidence map›Paper›PMID 42725000›Full record

ArticleCHEST pulmonary2026

Performance Characteristics and 2-Year Outcomes of Digital Tomosynthesis-Assisted Electromagnetic Navigation Bronchoscopy in a Community Hospital.

Elizabeth M Sain, Brandon T Rapier, Michael J Forte, Anuja L Sarode, Amber E Kerstetter-Fogle, Valerie Slezak, Brian D Bauman

Abstract read
In one paragraph

Article in CHEST pulmonary, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Elizabeth M SainSumma Health System Internal Medicine Residency Program, Akron, OH.
Brandon T RapierSumma Health System Pulmonary Disease and Critical Care Medicine Fellowship Program, Akron, OH.
Michael J FortePulmonary and Critical Care Medicine, Summa Health System Pulmonary Disease and Critical Care Medicine Fellowship Program, Department of Pulmonary and Critical Care Medicine, Summa Health System, Akron, OH.
Anuja L SarodeSumma Health, Research and Innovation, DISCOVER Center, Akron, OH.
Amber E Kerstetter-FogleSumma Health, Research and Innovation, DISCOVER Center, Akron, OH.
Valerie SlezakSumma Health System, Akron, OH.
Brian D BaumanPulmonary and Critical Care Medicine, Pulmonary Service Line, Respiratory Care, and Pulmonary Nodule Program, Summa Health System, Akron, OH.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The long-term performance characteristics of digital tomosynthesis-assisted electromagnetic navigation bronchoscopy (DT-ENB) has not been evaluated in the community setting. Research Question: What is the diagnostic yield and 2-year diagnostic accuracy of DT-ENB in a typical pulmonary practice? Study Design and Methods: This was a single-center, community hospital-based retrospective observational performance evaluation over 2 years assessing the long-term diagnostic accuracy of DT-ENB using the ILLUMISITE Fluoroscopic Navigation Platform (Medtronic). Other performance characteristics assessed included diagnostic yield, negative predictive value (NPV), and sensitivity. Factors affecting diagnostic yield were analyzed, and subsequent workup for false negatives and outcomes were described. Results: A total of 227 patients underwent DT-ENB, resulting in a specific diagnosis for 175 patients, for a diagnostic yield of 77.1% (95% CI, 71.2-82.1). Of these, 202 patients either had a confirmatory diagnosis or 2 years of CT scan follow-up. Among the 202 patients included in the NPV and sensitivity analysis, 135 (66.8%) were determined to be true positives, 47 (23.3%) were true negatives, 20 (9.9%) were false negatives, and there were no false positives. Overall, 2-year diagnostic accuracy was 71.4% (95% CI, 65.2-76.9). The 2-year NPV was 70.1% (95% CI, 61.0-78.0), and sensitivity was 87.1% (95% CI, 80.8-91.9). Nodule size was associated with higher diagnostic yield ( Interpretation: Our results show that DT-ENB when used in the community setting for lung nodule biopsy resulted in a diagnostic yield of 77.1% and diagnostic accuracy of 71.4% at 2-year follow-up.

Indexed as

diagnostic accuracydiagnostic yielddigital tomosynthesis-assisted ENBDT-ENBelectromagnetic navigation bronchoscopyENBlung nodulelung nodule biopsy

Identifiers

PMID42725000
PMCPMC13559987

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.