ArticleScientific reports2026
Analytical modeling and FEM simulation of slotted piezoelectric arrays for vibration energy harvesting.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This work investigates a cantilever-based piezoelectric energy harvester incorporating designs with different slot shapes. The finite element method and analytical modeling are employed to study and compare several slot geometries, including rectangular, triangular, symmetric H, asymmetric H, and inverted triangular designs. The results show that slot geometry and position strongly affect both output power and resonant frequency. The symmetric H-slot delivers nearly double the power output of the solid beam under the same conditions, along with a tenfold increase in voltage. The symmetric H-slot design achieves 0.64 mW at 47 Hz, corresponding to a normalized power density of 0.54 mW·cm⁻³·g⁻²·Hz⁻¹, confirming the effectiveness of the proposed structural modification in enhancing energy harvesting efficiency. Extending the design to slotted cantilever arrays revealed that uniform arrays provide a maximum power output of 1.86 mW, whereas varied-length H-slot arrays sacrifice power for a broader 5.8 Hz bandwidth with stable performance above 50% of peak.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.