ArticleRadiological physics and technology2026
Evaluation-design effects and reference-CT-defined HU-class errors in brain MRI-to-CT synthesis on SynthRAD2023: a technical note.
Article in Radiological physics and technology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
To quantify how evaluation design affects brain MRI-to-CT synthesis performance, we analyzed 180 MRI/CT pairs from three centers in the SynthRAD2023 Task 1 dataset. A lightweight 2D U-Net was trained with a common validation-based stopping rule under slice-random, patient-random, center-stratified size-matched patient-random, and three center-held-out designs. Comparisons were descriptive. The primary outcome was whole-mask mean absolute error (MAE), supplemented by MAE within reference-CT-defined Hounsfield unit (HU) classes. MAE (mean ± standard deviation) was 94.4 ± 3.0, 100.8 ± 1.3, and 105.2 ± 2.8 HU for the random designs and 187.4 ± 6.0, 160.6 ± 7.1, and 137.4 ± 5.1 HU for centers A, B, and C held out. Slice-random testing yielded lower MAE than patient-random testing. Center-held-out testing yielded higher MAE than the center-stratified comparator, although institutional and acquisition-domain effects could not be separated. Bone errors were high across designs; adipose-range and air errors were elevated in specific center-held-out tests.
Indexed as
Identifiers
42720881What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.