Evidence map›Paper›PMID 42719498›Full record

ArticleCureus2026

Effect of Marker Ball Positioning on Templating Accuracy in Hip Arthroplasty: A Closed-Loop Audit.

Heather Tetley, Marcus Cox, André Fernandes, Shaul Gordon, Jamie C Routledge, Smit Shah, Charlie Jowett

Abstract read
In one paragraph

Article in Cureus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Heather TetleyTrauma and Orthopaedics, York and Scarborough Teaching Hospitals NHS Foundation Trust, York, GBR.
Marcus CoxTrauma and Orthopaedics, York and Scarborough Teaching Hospitals NHS Foundation Trust, York, GBR.
André FernandesTrauma and Orthopaedics, York and Scarborough Teaching Hospitals NHS Foundation Trust, York, GBR.
Shaul GordonTrauma and Orthopaedics, York and Scarborough Teaching Hospitals NHS Foundation Trust, York, GBR.
Jamie C RoutledgeTrauma and Orthopaedics, Huddersfield Royal Infirmary, Huddersfield, GBR.
Smit ShahTrauma and Orthopaedics, York and Scarborough Teaching Hospitals NHS Foundation Trust, York, GBR.
Charlie JowettOrthopaedics, The York Hospital, York and Scarborough Teaching Hospitals NHS Foundation Trust, York, GBR.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction Positioning of external calibration devices (ECDs) in anteroposterior (AP) pelvic radiographs influences magnification correction and therefore the accuracy of digital templating in hip arthroplasty. Orthopaedic departments rely on radiology teams to accurately position ECDs on pre-operative radiographs, but due to multiple factors, placement is not always satisfactory, which may incorrectly guide selection of the hip prosthesis size. This closed-loop audit assessed the accuracy of templating femoral head size in patients with intra-capsular neck of femur (NOF) fractures before and after an instructional intervention for radiology staff on optimal marker ball placement. Methods A closed-loop retrospective audit was performed at York District Hospital, UK. Data were collected from September to December 2023 and March to May 2024. Inclusion criteria were trauma patients undergoing hip arthroplasty who had a templated pre-operative pelvic radiograph via TraumaCad software (Brainlab, Munich, Germany). The agreed audit standard was that 100% of pre-operative pelvic radiographs should contain a correctly positioned marker ball. The marker ball is a metal sphere, attached to a stand, used whilst obtaining a pelvic radiograph, as a calibration reference to accurately determine the true size and magnification of anatomical structures on the radiograph; this is used by the TraumaCad software to assist the template. Mean absolute head sizes were compared between digitally templated head sizes and implanted head sizes via intra-operative prosthetic stickers. Following the first cycle, results were presented at the departmental audit meeting, and a teaching session on marker ball positioning was delivered to radiology staff. The second cycle was conducted post intervention, and mean differences between templated and actual head sizes in both cycles were compared using a parametric unpaired t-test, with significance set at p < 0.05. Results In the first cycle, 52 patients met the audit inclusion criteria, of whom 50 (96.2%) had pre-operative pelvic radiographs with a fully visible marker ball. These 50 cases were included for accuracy analysis. The mean difference between templated and implanted head size was 2.82 mm (range: -5 to +11 mm); 24 patients (48%) received a larger head size than templated, 18 (36%) a smaller size, and six (12%) received the same size. Post intervention, 43 patients met the inclusion criteria in the second cycle. Of these, 37 (86.0%) had a fully visible marker ball and were included for analysis. The mean difference between templated and implanted head size decreased to 1.51 mm (range: -4 to +7 mm); 16 patients (43%) had larger actual head sizes, 12 (32%) had smaller, and nine (24%) had identical sizes. Statistical comparison demonstrated a significant improvement in templating accuracy between audit cycles (p = 0.008). However, despite the improvement in accuracy of head size selection, compliance with fully visible marker head balls in the radiograph decreased from 96.2% to 86.0%. Conclusion This quality improvement project demonstrates that a targeted educational intervention can significantly enhance the accuracy of radiological marker ball placement, leading to improved templating precision in hip arthroplasty.

Indexed as

digital templatinghemiarthroplastyhip fracturemarker balltotal hip replacement

Identifiers

PMID42719498
PMCPMC13557704

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.