Evidence map›Paper›PMID 42719135›Full record

ArticleAnnals of thoracic surgery short reports2026

Tidal Volume Discrepancy for Air Leak Detection in Thoracoscopic Lung Resection in Smokers.

Masaya Otabe, Masayuki Ishida, Atsushi Kamigaichi, Atsushi Kagimoto, Michiyoshi Sanuki, Takeshi Mimura

Abstract read
In one paragraph

Article in Annals of thoracic surgery short reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Masaya OtabeDepartment of General Thoracic Surgery, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure, Hiroshima, Japan.
Masayuki IshidaDepartment of General Thoracic Surgery, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure, Hiroshima, Japan.
Atsushi KamigaichiDepartment of General Thoracic Surgery, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure, Hiroshima, Japan.
Atsushi KagimotoDepartment of General Thoracic Surgery, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure, Hiroshima, Japan.
Michiyoshi SanukiDepartment of Anesthesiology, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure, Hiroshima, Japan.
Takeshi MimuraDepartment of General Thoracic Surgery, National Hospital Organization, Kure Medical Center and Chugoku Cancer Center, Kure, Hiroshima, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Prolonged air leakage (PAL) is a common postoperative complication after lung resection. The conventional air leak test, widely used to detect intraoperative air leaks, is limited to restricted thoracic space during lung inflation, which may result in undetected leaks, and fragile lung parenchyma may allow new air leaks to develop during chest closure. This study evaluated the efficacy of tidal volume discrepancy monitoring for intraoperative air leak detection during video-assisted thoracoscopic surgery anatomical lung resection (lobectomy and segmentectomy). Methods: We retrospectively reviewed 310 patients with a smoking history who underwent video-assisted thoracoscopic surgery anatomical lung resection for non-small cell lung cancer. Since May 2020, a new intraoperative air leak assessment method was implemented. After the conventional air leak test, bilateral lung ventilation was continued until chest closure, with continuous monitoring of inspired and expired tidal volumes. A sustained discrepancy >20 mL per breath prompted further intrathoracic inspection and repair. Results: PAL occurred in 4.1% of patients in the new method group, significantly lower than 10.9% in the conventional method group ( Conclusions: Intraoperative evaluation of intraoperative air leaks using tidal volume discrepancies is a reliable and effective method to detect air leaks and reduce PAL incidence in video-assisted thoracoscopic surgery anatomical lung resections.