Towards adaptive radiotherapy: Comparing HyperSight and standard CBCT reconstructions on a C-Arm Linac.

Niamh L Clarke, Jeremy L Hughes, Derrick Wanigaratne, Adam U Yeo

Abstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Niamh L ClarkeDepartment of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.ORCID https://orcid.org/0009-0005-7699-2741
Jeremy L HughesDepartment of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.
Derrick WanigaratneDepartment of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.ORCID https://orcid.org/0009-0000-0057-5689
Adam U YeoDepartment of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Victoria, Australia.ORCID https://orcid.org/0000-0002-9725-0668

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundCone-beam computed tomography (CBCT) is integral to image-guided radiation therapy and increasingly used for adaptive radiotherapy and CBCT-based dose calculation. Conventional kV-CBCT systems on C-arm TrueBeam linacs with Feldkamp-Davis-Kress (FDK) reconstruction have historically been limited by reduced Hounsfield Unit (HU) accuracy, scatter contamination, image noise and reconstruction artefacts. Iterative CBCT (iCBCT) reconstruction has improved image quality and HU consistency relative to the conventional FDK reconstruction. HyperSight represents a further evolution through software and hardware development with an enhanced detector design, advanced reconstruction algorithms and gantry rotation speeds up to 9°/s. PURPOSE: This study reports commissioning and evaluation of HyperSight iterative CBCT (HS-iCBCT) acquired on a Varian TrueBeam (v4.1), to support adaptive workflows in comparison with standard (Std-FDK) and iterative CBCT (Std-iCBCT) on a TrueBeam (v2.7). MATERIAL AND

methodsCBCT images were acquired on a Varian TrueBeam using the conventional kV On-board Imager (OBI) for Std-FDK and Std-iCBCT reconstructions and the HyperSight kV-imaging system for HS-iCBCT. Commissioning included CBCT dose calculation protocol optimization, CT-to-electron density (CT-ED) calibration and validation using STEEV, Rando and the CIRS Dynamic Thorax phantoms. CBCT images of anthropomorphic Head, Thorax/Spine, Rib and Lung phantoms were rigidly registered to the planning CT (pCT) and resampled using Velocity AI (v4.2). Voxel-wise HU difference histograms were generated, with peak position used to quantify systematic HU bias. Treatment plans (20 Gy/1# for Brain SRS/Spine, 24 Gy/2# for Rib and 54 Gy/3# for Lung) were optimized on the pCT and recalculated on the CBCT datasets. Dose-volume histogram (DVH) metrics were assessed and 3D-gamma analysis (2%/1 mm to 1%/1 mm; 10%/70% dose thresholds) was performed and compared with Std-FDK and Std-iCBCT.

resultsHS-iCBCT showed improved HU accuracy compared with Std-iCBCT and Std-FDK when benchmarked against the pCT. For materials ≤ 1.08 g/cm

conclusionsHyperSight reduces HU variability, improves image quality, and enhances CBCT-based dose calculation relative to conventional CBCT implementations. Use of a single optimized CBCT dose calculation protocol and baseline HU-ED calibration curve proved feasible across multiple anatomical sites, supporting implementation of HS-iCBCT for adaptive radiotherapy workflows on conventional C-arm TrueBeam linacs.

Indexed as

AlgorithmsCone-Beam Computed TomographyImage Processing, Computer-AssistedParticle AcceleratorsPhantoms, ImagingRadiotherapy, Image-GuidedRadiotherapy Planning, Computer-AssistedHumansRadiotherapy DosageRadiotherapy, Intensity-Modulatedadaptive radiation therapyadvanced imagingHyperSightIGRT

Identifiers

PMID42717692
PMCPMC13559172