Evidence map›Paper›PMID 42717196›Full record

ArticleNature communications2026

Modulating pressure in the Orbitrap improves sensitivity and mass resolution in charge detection mass spectrometry.

Eduard H T M Ebberink, Elena Giaretta, Arjan Barendregt, Jan Fiala, Victor C Yin, Tobias P Wörner, Kyle L Fort, Alexander A Makarov, Albert J R Heck

Abstract read
In one paragraph

Article in Nature communications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Eduard H T M EbberinkBiomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands.
Elena GiarettaBiomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands.ORCID http://orcid.org/0009-0001-2351-2581
Arjan BarendregtBiomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands.
Jan FialaBiomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0002-7753-8170
Victor C YinBiomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0003-0104-0293
Tobias P WörnerThermo Fisher Scientific (Bremen) GmbH, Bremen, Germany.
Kyle L FortBiomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands.
Alexander A MakarovBiomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands.ORCID http://orcid.org/0000-0002-7046-6709
Albert J R HeckBiomolecular Mass Spectrometry and Proteomics, Bijvoet Center for Biomolecular Research and Utrecht Institute for Pharmaceutical Sciences, Utrecht University, Utrecht, The Netherlands. a.j.r.heck@uu.nl.ORCID http://orcid.org/0000-0002-2405-4404

Funding

Nederlandse Organisatie voor Wetenschappelijk Onderzoek (Netherlands Organisation for Scientific Research) Spinoza Award SPI.2017.028
6 · The paper itself

Abstract

Native mass spectrometry has become a key method for studying macromolecular assemblies, providing insights into structures, stoichiometries, and binding interactions. A key aspect for the transmission of electrospray-generated bioparticles into the mass analyzer is the use of gas for collisional cooling and ion desolvation. However, in Orbitrap-based mass spectrometry, the elevated pressure may negatively affect ions, as collisions with background gas can destabilize ion trajectories, potentially leading to incorrect mass determination. These effects are amplified when the pressure in the collision cell is high, as required for large biological assemblies, and when ions are measured for (ultra)long acquisition times in the Orbitrap, as required for high-resolution mass spectrometry. To address these issues, we modified a standard Q Exactive™ UHMR by installing a pulsed valve to control gas flow and limit gas leakage into the Orbitrap. This way, ion transmission and desolvation are maintained while the ultrahigh vacuum in the mass analyzer is enhanced during acquisition. We show that this improves ion detection of various assemblies, including adeno-associated viruses, IgM, and plasmid DNA, with superior mass accuracy and resolving power. The pulsed valve implementation will benefit nearly all mass measurements, setting the stage for next-generation Orbitrap-based, single-ion mass spectrometry.

Indexed as

Mass SpectrometrySpectrometry, Mass, Electrospray IonizationIonsPressureIons

Identifiers

PMID42717196
PMCPMC13558686

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.