ArticleScientific reports2026
Code-based refinement and finite element validation of punching shear design for reinforced concrete footings.
Article in Scientific reports, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Punching shear failure of reinforced concrete (RC) footings is strongly influenced by soil-structure interaction; however, current design codes evaluate footing punching capacity using slab-based empirical formulations. This study presents a code-based refinement and Finite Element Model (FEM) validation of punching shear design for reinforced concrete (RC) isolated footings resting on soil. A three-dimensional nonlinear Finite Element Model (FEM) was developed in PLAXIS 3D to simulate concrete cracking and crushing, Reinforcement yielding, soil plasticity, and concrete-soil interface behavior. The model was validated against experimental results from nine square footings (750 × 750 × 120 mm) tested under monotonic vertical loading. Numerical predictions of ultimate punching load and load-settlement response agreed well with experiments, with discrepancies limited to ± 10% and coefficients of variation not exceeding 1.11%. A comprehensive parametric study comprising 81 finite element models was then conducted to investigate the effects of concrete compressive strength (34, 42, and 61 MPa), column aspect ratio (a/b = 1, 2, and 3), punching shear Reinforcement (none, 8Ø6, and 8Ø8), and soil stiffness (sand, sand-crushed limestone mixture, and crushed limestone). Results showed that increasing concrete strength enhanced punching capacity by up to 34%, while increasing column aspect ratio increased capacity by up to 74%. Soil stiffness was identified as a governing parameter, increasing punching capacity by up to 20%, subgrade reaction by up to 200%, and reducing settlement by up to 75%. ACI 318 and ECP 203 predictions exhibited significant scatter when directly applied to footings. A refined punching shear expression was therefore proposed by introducing a correction factor derived from the finite element results. The soil-related factor (η₃ = ln(5000kₛ)) was found to dominate, while other correction factors remained unity within the investigated ranges. The proposed formulation significantly improves the reliability of punching shear design for RC footings by explicitly accounting for soil stiffness effects.