Evidence map›Paper›PMID 42714213›Full record

ArticleJournal of applied clinical medical physics2026

Quantitative Cherenkov-excited fluorescence emission dosimetry for HDR Co-60 brachytherapy: Calibration and planar validation against TPS.

Yagiz Yedekci, Mehmet Fazıl Enkavi, Ferah Yildiz

Abstract readValidation Study
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yagiz YedekciDepartment of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara, Turkey.ORCID https://orcid.org/0000-0001-9448-8278
Mehmet Fazıl EnkaviDepartment of Radiation Oncology, Medicana International Ankara Hospitals, Ankara, Turkey.
Ferah YildizDepartment of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara, Turkey.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate dose verification in High-Dose-Rate (HDR) brachytherapy presents a significant challenge due to steep dose gradients and the absence of beam collimation. Conventional quality assurance (QA) methods typically rely on point detectors or film-based techniques, which lack the capability to provide real-time, full-field visualization of dose distributions in a water-equivalent medium. While Cherenkov emission (CE) imaging has been investigated for Iridium-192 ( PURPOSE: This study aims to characterize the relationship between Cherenkov emission intensity and absorbed dose generated by an HDR

methodsA custom 3D-printed polylactic acid (PLA) phantom was fabricated with an internal cavity filled with an aqueous quinine hemisulfate solution (1 g/L). This solution was used to convert ultraviolet Cherenkov photons into isotropic visible fluorescence, thereby enhancing optical signal detection. Optical emissions were captured using a standard monochrome CMOS camera positioned at a 24 cm working distance. To eliminate radiation-induced artifacts on the sensor without relying on complex time-gated hardware, an image processing pipeline comprising dark frame subtraction, median filtering, and morphological operations was applied. A calibration function was established by delivering doses between 10 and 1500 cGy using a

resultsThe dosimetric calibration demonstrated a highly predictable and linear dose-response relationship, yielding a coefficient of determination (R

conclusionThe integration of Cherenkov-excited fluorescence imaging with a standard CMOS sensor provides a highly linear, practical, and cost-effective planar dose verification tool for continuous-emission

Indexed as

BrachytherapyCobalt RadioisotopesPhantoms, ImagingQuality Assurance, Health CareRadiometryRadiotherapy Planning, Computer-AssistedCalibrationHumansIridium RadioisotopesMonte Carlo MethodRadiotherapy DosageCobalt-60Cobalt RadioisotopesIridium Radioisotopes60Co brachytherapyCherenkov emissionfluorescenceoptical dosimetryquality assurance

Identifiers

PMID42714213
PMCPMC13556302

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.