Re-evaluating haemolysis rejection criteria for PT, aPTT, and D-dimer testing: evidence from paired clinical samples on the CN-3000 analyser.

Jirapa Kaewkhruawan, Wararat Masalae, Surapat Tanticharoenkarn, Pitchayaporn Riyagoon, Waroonkarn Laiklang, Kwanlada Chaiwong, Suppakorn Wongkamchai, Phandee Watanaboonyongcharoen, Chutitorn Ketloy, Orakan Limpornpugdee and 1 more

Abstract read
In one paragraph

Article in Advances in laboratory medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Jirapa KaewkhruawanDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Wararat MasalaeDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Surapat TanticharoenkarnDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Pitchayaporn RiyagoonDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Waroonkarn LaiklangDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Kwanlada ChaiwongDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Suppakorn WongkamchaiDivision of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.
Phandee WatanaboonyongcharoenDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0000-0002-8270-5308
Chutitorn KetloyDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0000-0002-7043-8062
Orakan LimpornpugdeeDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0009-0000-1790-9841
Eakachai PrompetcharaDepartment of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.ORCID https://orcid.org/0000-0001-7565-9211

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objectives: Haemolysis is the leading preanalytical cause of sample rejection in coagulation testing. This study prospectively evaluated the impact of spontaneous haemolysis on routine haemostasis assays by comparing paired haemolysed (H) and non-haemolysed (NH) clinical samples. Additionally, analyser flagging behaviour was characterised using an artificially haemolysed sample series. Methods: Thirty nine paired of H and NH samples were analysed for prothrombin time (PT), activated partial thromboplastin time (aPTT), and D-dimer (DD) on the Sysmex CN-3000. Mean biases were compared against predefined critical differences (CD) derived from biological variation data. Analyser flagging was additionally assessed using five sample pools across five haemolysis concentration levels (H1-H5). Results: When comparing H samples with NH samples, the mean bias was +0.07 s (+0.14 %) for PT (p=0.5979), +0.44 s (+0.66 %) for aPTT (p=0.8704), and +0.72 mg/L FEU (+10.63 %) for D-dimer (p=0.0199). D-dimer showed the highest relative bias but remained below the CD (64.7 %). Degree of haemolysis did not predict the magnitude of interference across the range of haemoglobin (Hb) concentrations studied. CN-3000 flagging grades were constant and correlated free Hb and irrespective of baseline sample PT/aPTT/D-dimer level. Conclusions: Mild to moderate spontaneous haemolysis does not produce clinically significant interference in PT, aPTT, or D-dimer. CN-3000 flagging behaviour is predictable and grade-dependent. Re-evaluation of automatic haemolysis rejection thresholds is warranted.

Indexed as

analyser flaggingcoagulation testshaemolysispreanalytical phasesample rejection