Evidence map›Paper›PMID 42712733›Full record

ArticleJournal of the Society for Cardiovascular Angiography & Interventions2026

Exploring a Novel Processing Algorithm to Improve Image Quality and Reduce X-Ray and Contrast Dose for Coronary Angiography: A Blinded Pilot Study.

Saba Assar, Mark Winkens, Kajo van der Marel, Roy van Pelt, Lindsay Johnson, Martijn S van Mourik, Ragui Ibrahim, Philippe L'Allier, Lim Soo Teik, Leah Raj and 3 more

Abstract read
In one paragraph

Article in Journal of the Society for Cardiovascular Angiography & Interventions, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Saba AssarColumbia University Irving Medical Center/NewYork-Presbyterian Hospital, New York, New York.
Mark WinkensETZ Tweesteden, Tilburg, the Netherlands.
Kajo van der MarelPhilips Image Guided Therapy System, Best, the Netherlands.
Roy van PeltPhilips Image Guided Therapy System, Best, the Netherlands.
Lindsay JohnsonPhilips Image Guided Therapy System, Best, the Netherlands.
Martijn S van MourikPhilips Image Guided Therapy System, Best, the Netherlands.
Ragui IbrahimHôpital Pierre-Boucher, Longueuil, Quebec, Canada.
Philippe L'AllierMontreal Heart Institute, Montreal, Quebec, Canada.
Lim Soo TeikNational Heart Centre Singapore, Singapore.
Leah RajEmory Healthcare, Atlanta, Georgia.
William NicholsonEmory Healthcare, Atlanta, Georgia.
Michael CollinsColumbia University Irving Medical Center/NewYork-Presbyterian Hospital, New York, New York.
Ajay J KirtaneColumbia University Irving Medical Center/NewYork-Presbyterian Hospital, New York, New York.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: With advancements in percutaneous coronary intervention, clinicians face the challenge of balancing the need for high-quality imaging with the imperative to minimize radiation exposure and iodinated contrast use, particularly in complex procedures. Methods: We conducted a pilot study of 50 patients undergoing diagnostic coronary angiography in which each patient received 2 sequential angiograms, one using conventional image acquisition and processing protocols and the other acquired and processed using a novel algorithm, with a reduction in radiation, iodine content, or both. Angiographic runs were analyzed offline by 5 interventional cardiologists who independently reviewed the images, blinded to the image acquisition protocol. The study assessed image quality between the 2 acquisition protocols as well as interobserver variability to measure consistency in scoring among the evaluators. Results: The mean age of the patients was 63 ± 10 years (74% male). The mean body mass index was 27.8 ± 5.0 kg/m Conclusions: These data suggest that the use of novel x-ray acquisition algorithms can improve image quality while maintaining or lowering radiation or iodine dose. The prospective evaluation of these algorithms within routine clinical practice is warranted in future clinical studies.

Indexed as

contrast exposurecoronary angiographyradiation exposurex-ray acquisition algorithm

Identifiers

PMID42712733
PMCPMC13550899

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.