ArticleAnalytical chemistry2026
Locked Nucleic Acid and Minor Groove Binder Probes Improve the Specificity of Isothermal Amplification Detection.
Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
Isothermal amplification reactions have diverse applications in molecular diagnostics, point-of-care detection, and synthesis of nucleic acids. Isothermal amplification techniques eliminate the need for temperature cycling and the related equipment. However, a common issue of isothermal amplification is the formation of nonspecific amplification byproducts that cause false-positive detection. We report here the development and design principles of sequence-specific minor groove binder (MGB) and locked nucleic acid (LNA) probes, which significantly improve the detection specificity. We show an example of integrating loop-mediated isothermal amplification (LAMP) with the MGB and LNA probes and demonstrate an application of the integrated method to the specific detection of Streptococcus pyogenes (group A streptococcus [GAS]) and skin and wound specimens. The technique reduced background and eliminated false positives generated by nonspecific amplification byproducts. The method achieved a detection limit of 25 copies of the target speB DNA with a 30 min LAMP-probe reaction. Results from the analysis of 171 skin and wound specimens were consistent with clinical diagnostics of GAS infections, confirming 100% positive predictive value (PPV) and 100% negative predictive value (NPV) of the assay. The modular design of LAMP and the MGB and LNA detection probes can be readily adapted for the detection of other nucleic acid targets.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.