Evidence map›Paper›PMID 42708719›Full record

ArticleAnalytical chemistry2026

Locked Nucleic Acid and Minor Groove Binder Probes Improve the Specificity of Isothermal Amplification Detection.

Yanming Liu, Xiaotian Ma, Jianyu Hu, Gregory J Tyrrell, Petrus J van der Walt, Xing-Fang Li, X Chris Le

Abstract read
In one paragraph

Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Yanming LiuDivision of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AlbertaT6G 2G3, Canada.ORCID 0000-0003-2819-775X
Xiaotian MaDivision of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AlbertaT6G 2G3, Canada.
Jianyu HuDivision of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AlbertaT6G 2G3, Canada.ORCID 0000-0003-2754-2339
Gregory J TyrrellDivision of Diagnostic and Applied Microbiology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AlbertaT6G 2J2, Canada.
Petrus J van der WaltDivision of Diagnostic and Applied Microbiology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AlbertaT6G 2J2, Canada.
Xing-Fang LiDivision of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AlbertaT6G 2G3, Canada.ORCID 0000-0003-1844-7700
X Chris LeDivision of Analytical and Environmental Toxicology, Department of Laboratory Medicine and Pathology, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, AlbertaT6G 2G3, Canada.ORCID 0000-0002-7690-6701

Funding

Biosciences Research Infrastructure Fund NACanada Research Chairs program NACanadian Biomedical Research Fund NANatural Sciences and Engineering Research Council of Canada NA
6 · The paper itself

Abstract

Isothermal amplification reactions have diverse applications in molecular diagnostics, point-of-care detection, and synthesis of nucleic acids. Isothermal amplification techniques eliminate the need for temperature cycling and the related equipment. However, a common issue of isothermal amplification is the formation of nonspecific amplification byproducts that cause false-positive detection. We report here the development and design principles of sequence-specific minor groove binder (MGB) and locked nucleic acid (LNA) probes, which significantly improve the detection specificity. We show an example of integrating loop-mediated isothermal amplification (LAMP) with the MGB and LNA probes and demonstrate an application of the integrated method to the specific detection of Streptococcus pyogenes (group A streptococcus [GAS]) and skin and wound specimens. The technique reduced background and eliminated false positives generated by nonspecific amplification byproducts. The method achieved a detection limit of 25 copies of the target speB DNA with a 30 min LAMP-probe reaction. Results from the analysis of 171 skin and wound specimens were consistent with clinical diagnostics of GAS infections, confirming 100% positive predictive value (PPV) and 100% negative predictive value (NPV) of the assay. The modular design of LAMP and the MGB and LNA detection probes can be readily adapted for the detection of other nucleic acid targets.

Indexed as

Molecular Diagnostic TechniquesNucleic Acid Amplification TechniquesOligonucleotidesStreptococcus pyogenesTemperatureDNA, BacterialHumansSkinDNA, Bacteriallocked nucleic acidOligonucleotides

Identifiers

PMID42708719
PMCPMC13564035

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.