Evidence map›Paper›PMID 42708716›Full record

ArticleAnalytical chemistry2026

Miniaturization of Aptasensors in Organic Electrochemical Transistors for Sensitivity Enhancement.

Andika Asyuda, Rasheed T Odunbaku, Luka J L Striethorst, Henrique F P Barbosa, Andreas Schander, Ramesh Kumar, Dur E N Gakhar, Sarah Bornemann, Rachel E Armstrong, Björn Lüssem

Abstract read
In one paragraph

Article in Analytical chemistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Andika AsyudaInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.ORCID 0000-0002-4375-4270
Rasheed T OdunbakuInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.
Luka J L StriethorstInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.ORCID 0009-0005-5772-6771
Henrique F P BarbosaInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.ORCID 0000-0001-9130-5755
Andreas SchanderInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.
Ramesh KumarInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.
Dur E N GakharInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.
Sarah BornemannInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.ORCID 0000-0002-1840-3591
Rachel E ArmstrongOnePlanet Research Center, Wageningen6708 WH, The Netherlands.
Björn LüssemInstitut für Mikrosensoren, Aktoren, und -Systeme (IMSAS), Universität Bremen, Bremen28359, Germany.

Funding

Deutsche Forschungsgemeinschaft 524736815Deutsche Forschungsgemeinschaft LU 1464/3-1Universit?t Bremen NA
6 · The paper itself

Abstract

Aptasensors have received intense interest because of their selectivity and synthetic flexibility. Aptamer bioreceptors were recently combined with organic electrochemical transistors (OECTs) to increase the signal strength. Although promising, a lack of fundamental understanding of the scaling of these OECT-based aptasensors makes targeted optimization of these devices challenging. Here, we study the influence of the gate electrode area on sensitivity, detection range, and selectivity systematically. To increase the ratio between gate and channel area further, we, for the first time, combine the aptasensor with a vertical OECT (VOECT), yielding a sensitivity as high as 0.3 mA/dec. Furthermore, the response of the OECT aptasensor is already significant at gate voltages close to 0 V, thus avoiding undesired electrochemical processes such as gold oxidation or radical oxygen formation. Overall, the combination of OECT and aptasensor serves as an important step toward a miniaturized biosensor with amplified sensitivity and continuous sensing capability. The present study not only extends our understanding of gate scaling on the sensor response but also provides design rules to reach very high sensitivity at low operational voltages.

Identifiers

PMID42708716
PMCPMC13564037

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.