Generalized self-calibrating probe approach for CW tissue oximetry.

Leila Motamed Jahromi, Lin Yang, Alexander von Lühmann, Dirk Grosenick

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Leila Motamed JahromiPhysikalisch-Technische Bundesanstalt (PTB), Berlin, Germany.ORCID https://orcid.org/0000-0001-6954-520X
Lin YangPhysikalisch-Technische Bundesanstalt (PTB), Berlin, Germany.ORCID https://orcid.org/0000-0003-3266-6061
Alexander von LühmannNIRx Medizintechnik GmbH, Berlin, Germany.ORCID https://orcid.org/0000-0002-4995-293X
Dirk GrosenickPhysikalisch-Technische Bundesanstalt (PTB), Berlin, Germany.ORCID https://orcid.org/0009-0005-4354-7254

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: Functional near-infrared spectroscopy (fNIRS) and oximetry are important noninvasive methods to investigate physiological processes and states in the human brain and muscle tissue. Self-calibrating probe methods combine two light sources with typically two detectors to improve the stability of continuous-wave (CW) devices, but so far are limited to fully symmetric geometries. Aim: We developed a generalized self-calibrating probe approach to improve accuracy and stability in CW oximetry for arbitrary configurations of two light sources and detectors. Approach: We used the diffusion theory of light transport to derive the effective attenuation coefficient from self-calibrating probes with arbitrary asymmetric source-detector configurations in reflection. The theory was validated by measurements on tissue-like reference phantoms and by a vascular occlusion test on the forearm muscle of a healthy subject using a dual-wavelength CW fNIRS imager. Results were compared with conventional analysis by spatially resolved spectroscopy (SRS). Time-domain measurements served as a reference. Results: The phantom studies with the generalized self-calibrating probe approach provided accurate results for effective attenuation and oxygen saturation for the wide variety of source-detector configurations examined. Results from the SRS method showed a slightly larger spread. When submillimeter shifts of the source positions were neglected in the data analysis, large errors were observed in oxygen saturation for both methods. The vascular occlusion test showed good agreement between the self-calibrating approach and the time-domain reference data. Oxygenation profiles from SRS differed strongly across the source-detector combinations, with significant deviations already for the baseline saturation. When CW measurements were analyzed using literature values for the tissue scattering properties, systematic shifts of the oxygen saturation occured. The shifts remain small when the ratio of the reduced scattering coefficients at the two wavelengths of the CW device is close to the true tissue value. Conclusions: The proposed generalized self-calibrating approach enables quantification of oxygen saturation

Indexed as

OximetryAlgorithmsCalibrationForearmHumansMuscle, SkeletalOxygenOxygen SaturationPhantoms, ImagingSpectroscopy, Near-InfraredOxygendiffusion modelnear-infrared spectroscopyoximetryspatially resolved spectroscopy

Identifiers

PMID42707729
PMCPMC13549469

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.