Evidence map›Paper›PMID 42707117›Full record

Observational studyFrontiers in neurology2026

Temporary flow arrest using EMBOGUARD™ balloon guide catheter may improve functional outcomes in acute stroke thrombectomy: a multicenter retrospective study.

Rami Z Morsi, Sophia Falk, Elena Badillo Goicoechea, Taraf Jaro, Archit B Baskaran, Sonam Thind, Khalid Trad, Ahmad Khaldi, Reem El-Ghawanmeh, Violiza Inoa and 10 more

Abstract readMulticenter StudyObservational Study
In one paragraph

Observational study in Frontiers in neurology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

20 authors.

Rami Z MorsiDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Sophia FalkDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Elena Badillo GoicoecheaDepartment of Public Health Sciences, University of Chicago, Chicago, IL, United States.
Taraf JaroDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Archit B BaskaranDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Sonam ThindDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Khalid TradDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Ahmad KhaldiDepartment of Neurosurgery, Wellstar Health System, Marietta, GA, United States.
Reem El-GhawanmehDepartment of Neurology, University of Tennessee Health Science Center, Memphis, TN, United States.
Violiza InoaDepartment of Neurology, University of Tennessee Health Science Center, Memphis, TN, United States.
Mohammad H AlMajaliNeuroscience and Stroke Program, Bon Secours Mercy Health St Vincent Hospital, Toledo, OH, United States.
Amit ChaudhariNeuroscience and Stroke Program, Bon Secours Mercy Health St Vincent Hospital, Toledo, OH, United States.
Yazan AshouriNeuroscience and Stroke Program, Bon Secours Mercy Health St Vincent Hospital, Toledo, OH, United States.
Osama O ZaidatNeuroscience and Stroke Program, Bon Secours Mercy Health St Vincent Hospital, Toledo, OH, United States.
Mahmood MirzaResearch Department, Johnson & Johnson Medtech Neurovascular, Galway, Ireland.
Rachel MehendaleDepartment of Neurology, University of Chicago, Chicago, IL, United States.
James E SieglerDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Ali MansourDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Shyam PrabhakaranDepartment of Neurology, University of Chicago, Chicago, IL, United States.
Tareq Kass-HoutDepartment of Neurology, University of Chicago, Chicago, IL, United States.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Balloon guide catheters (BGCs) have demonstrated benefits in mechanical thrombectomy (MT) for acute ischemic stroke (AIS), including improved recanalization rates and reduced distal embolization. The EMBOGUARD™ balloon guide catheter (Johnson & Johnson Neurovascular, Irvine, CA) represents a novel design with enhanced flexibility and compatibility with large-bore aspiration catheters. This study aims to evaluate the safety and efficacy of the EMBOGUARD™ BGC compared with non-BGC approaches. Methods: We conducted a retrospective multicenter study to analyze patients with AIS due to anterior large vessel occlusions (LVOs) who underwent MT between January 2022 and December 2024. Patients were divided into two groups: those treated with t☺he EMBOGUARD™ BGC and those treated without BGC. Primary outcomes included first-pass effect (FPE), successful recanalization (mTICI ≥2b), procedural time, number of passes, and distal embolization. Secondary outcomes included 90-day functional outcome (modified Rankin Scale [mRS] 0-2), mortality, and symptomatic intracranial hemorrhage (sICH). Results: A total of 178 patients were included (EMBOGUARD: Conclusion: The EMBOGUARD™ balloon guide catheter demonstrated comparable technical efficacy with reduced procedural times and improved clinical outcomes compared with non-BGC techniques in endovascular thrombectomy for acute ischemic stroke. These findings support the use of EMBOGUARD™ as a reasonable tool for flow arrest in stroke intervention.

Indexed as

Ischemic StrokeStrokeThrombectomyAgedAged, 80 and overFemaleHumansMaleMiddle AgedRetrospective StudiesTreatment Outcomeballoon guide catheterflow arrestischemic strokeretrospectivethrombectomy

Identifiers

PMID42707117
PMCPMC13547071

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.