Evidence map›Paper›PMID 42703740›Full record

ArticleMedical physics2026

Dual-branch MRI denoising and motion artifact suppression with uncertainty estimation and segmentation-based evaluation.

Mingfu Jiang, Chi Kin Lam, Zhuoneng Zhang, Poorya MohammadiNasab, Hing-Chiu Chang, Tong Tong, Hualong She, Zhen Yuan, Tao Tan

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Mingfu JiangFaculty of Applied Sciences, Macao Polytechnic University, Macao, China.
Chi Kin LamFaculty of Applied Sciences, Macao Polytechnic University, Macao, China.
Zhuoneng ZhangFaculty of Applied Sciences, Macao Polytechnic University, Macao, China.
Poorya MohammadiNasabCenter for Medical Physics and Biomedical Engineering, Medical University Vienna, Vienna, Austria.
Hing-Chiu ChangDepartment of Biomedical Engineering, Chinese University of Hong Kong, Hong Kong, China.
Tong TongCollege of Physics and Information Engineering, Fuzhou University, Fuzhou, Fujian, China.
Hualong SheThe Third People's Hospital of Chenzhou City, Chenzhou, Hunan, China.
Zhen YuanFaculty of Health Sciences, University of Macau, Macao, China.
Tao TanFaculty of Applied Sciences, Macao Polytechnic University, Macao, China.

Funding

Macao Polytechnic University Grant RP/FCA-05/2022Macao Polytechnic University Grant RP/FCA-09/2025Science and Technology Development Fund Macau SARunder the FDCT-FAPESP Joint Funding Scheme 0004/2025/ASJScience and Technology Development Fund of Macao 0105/2022/AShenzhen Medical Research Fund D2501013
6 · The paper itself

Abstract

backgroundMagnetic resonance (MR) images are essential for clinical diagnosis, yet their quality is often compromised by noise and motion artifacts, potentially obscuring anatomical details and reducing diagnostic accuracy. Existing deep learning approaches frequently address denoising and motion artifact suppression as separate tasks, overlook pixel correlations and varying noise levels, require manual parameter tuning, and lack uncertainty evaluation, thus limiting their practical utility in clinical settings. PURPOSE: This study aims to develop a Dual-branch MRI Denoising and Motion Artifact Suppression with Uncertainty Estimation and Segmentation-based Evaluation (DbUSNet). The model is designed to adaptively handle varying noise and motion artifact levels, preserve complex structural details, and provide uncertainty estimates for the processed outputs. This may offer insights into downstream clinical tasks such as image segmentation.

methodsThe DbUSNet integrates two specialized branches: A Heterogeneous Window Transformer Network (HWTNet) for adaptive denoising using both local and global feature modeling, and an improved U-Net based Motion Artifact Suppression Network (ASNet). Each branch is coupled with an estimation subnetwork-Noise Estimation Subnetwork (NES) and Artifact Estimation Subnetwork (AES)-to dynamically assess and adapt to input specific degradation levels. The outputs of both branches are fused via an attention-based fusion module. Uncertainty is quantified during inference using Monte Carlo (MC) dropout. The model was trained and tested on brain MR scans from Brats2021 dataset (2000 samples), OpenNeuro dataset (22 samples), and MR-ART dataset (148 samples), incorporating synthetic Rician noise and motion artifacts. Downstream segmentation performance was evaluated on the Medical Segmentation Decathlon (MSD) brain dataset (1666 samples) and a prostate MR dataset (203 samples).

resultsOn the Brats2021, OpenNeuro, and MR-ART testsets, DbUSNet achieved PSNR of 28.23 dB, 27.13 dB, and 27.83 dB, SSIM of 0.93, 0.91, and 0.92, NMSE of 0.08, 0.08, and 0.08, respectively. For the downstream segmentation task, the denoised and motion artifact suppressed outputs led to average Dice score improvements of 3.10%, 3.59%, 2.46%, and 2.15% for T1, T1ce, FLAIR, and T2 modalities in the MSD brain dataset, and 2.16% and 2.24% for T2 and ADC sequences in the prostate dataset.

conclusionThe DbUSNet framework jointly performs adaptive denoising and motion artifact suppression within a unified pipeline and enables pixel-wise uncertainty quantification. Evaluations on controlled brain MRI datasets show consistent image quality gains and improved downstream segmentation performance, though the limited size and healthy-only composition of real motion test cohorts restrict wide clinical extrapolation. This work delivers a feasible technical prototype for MR image enhancement; larger, diverse clinical patient datasets will be required to further validate its clinical utility.

Indexed as

ArtifactsImage Processing, Computer-AssistedMagnetic Resonance ImagingSignal-To-Noise RatioHumansMotionMovementUncertaintyadaptivesimultaneous denoising and motion artifact suppressionuncertainty estimation

Identifiers

PMID42703740
PMCPMC13548186

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.