Evidence map›Paper›PMID 42701918›Full record

ArticleInternational journal of computer assisted radiology and surgery2026

Automatic probe guidance for volumetric liver ultrasound acquisition via imitation learning from a virtual expert.

Taiyu Han, Hanying Liang, Qi Zeng, Yan Kang, Hongen Liao, Guochen Ning, Septimiu E Salcudean

Abstract read
PubMed Publisher
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Taiyu Han *College of Applied Sciences, Shenzhen University, Shenzhen, China.
Hanying Liang *School of Biomedical Engineering, Tsinghua University, Beijing, 10084, China.
Qi ZengDepartment of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada.
Yan KangCollege of Health Science and Environmental Engineering, Shenzhen Technology University, Shenzhen, China.
Hongen LiaoSchool of Biomedical Engineering, Tsinghua University, Beijing, 10084, China.
Guochen NingSchool of Biomedical Engineering, Tsinghua University, Beijing, 10084, China. ningguochen@tsinghua.edu.cn.ORCID http://orcid.org/0000-0003-0282-7303
Septimiu E SalcudeanDepartment of Electrical and Computer Engineering, University of British Columbia, Vancouver, BC V6T 1Z4, Canada. tims@ece.ubc.ca.

Funding

National Key Research and Development Program of China 2025YFC2425700National Natural Science Foundation of China 82472115
6 · The paper itself

Abstract

purposeVolumetric liver ultrasound (US) plays an important role in clinical diagnosis but remains highly dependent on operator expertise, particularly during target view localization. This study aims to develop an automatic probe guidance framework that reduces reliance on manual demonstrations and additional sensing hardware, while supporting robust volumetric liver US acquisition.

methodsWe propose an image-based imitation learning framework that learns probe guidance policies from a virtual expert in a simulated US scanning environment. A simulation pipeline is constructed using cross-modal medical images and a hybrid US simulator that combines physics-based ray casting with generation-based image synthesis to produce anatomically consistent and acoustically realistic US images. Optimal scanning trajectories are generated based solely on target views typically available in clinical practice. To improve robustness, pose-level and image-level data augmentations are introduced, and US observations are encoded into an anatomy-aware state representation for intercostal liver scanning.

resultsExperimental results in simulation and real clinical data demonstrate that the proposed framework achieves accurate and stable target view localization for volumetric liver US acquisition. Compared with baseline and ablated models, the method shows improved localization accuracy, increased liver coverage, and reduced rib interference, while maintaining robustness across different anatomical conditions.

conclusionThis work presents a data-efficient and clinically practical solution for automatic probe guidance in volumetric liver US. By leveraging realistic simulation, virtual expert demonstrations, and anatomy-aware image representations, the proposed framework enables effective learning of probe movements without requiring manual trajectory annotations or additional sensors. The results suggest strong potential for integration into computer-assisted and robotic US systems.

Indexed as

Data simulationImitation learningProbe guidanceTarget view localizationVolumetric liver ultrasound

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.