Evidence map›Paper›PMID 42701614›Full record

ArticleQuantitative imaging in medicine and surgery2026

Segment-resolved assessment of hydration effects on liver water-specific T1 in comparison with T1-MOLLI and transient elastography.

Robert Leon Walter, Elizabeth Huaroc Moquillaza, Waldemar Sapototzki, Vincenz Sahm, Fabian Geisler, Lukas Endrös, Kilian Weiss, Mariya Doneva, Dimitrios C Karampinos, Lisa Steinhelfer and 1 more

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Robert Leon Walter *Institute of Neuroradiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.ORCID https://orcid.org/0000-0002-7088-736X
Elizabeth Huaroc Moquillaza *Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
Waldemar SapototzkiInstitute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
Vincenz SahmInstitute of Internal Medicine II, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
Fabian GeislerInstitute of Internal Medicine II, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
Lukas EndrösDepartment of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
Kilian WeissPhilips GmbH, Market DACH, Hamburg, Germany.
Mariya DonevaPhilips Innovative Technologies, Hamburg, Germany.
Dimitrios C KarampinosLaboratory of Magnetic Resonance Imaging Systems and Methods, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.
Lisa Steinhelfer *Institute of Neuroradiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.
Rickmer Braren *Institute for Diagnostic and Interventional Radiology, School of Medicine and Health, TUM University Hospital, Technical University of Munich, Munich, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Quantitative liver T1 mapping is a promising noninvasive biomarker for diffuse liver disease, but it is influenced by physiological variability. Hydration alters tissue water content and perfusion, yet its effect on liver water-specific T1 (wT1) remains poorly characterized, particularly across liver segments. Prior studies relied on single-slice acquisitions, limiting assessment of spatial heterogeneity. The objective is to assess hydration-related changes in liver wT1 across all Couinaud segments using an accelerated multi-slice technique and to compare results with single-slice T1-modified Look-Locker inversion recovery (T1-MOLLI) and vibration-controlled transient elastography (VCTE). Methods: Twenty-nine healthy adults underwent blood sampling, VCTE, and liver magnetic resonance imaging (MRI) after an ≥8-hour fast without fluid intake and again after ingestion of 1 L of water followed by a 1-hour equilibration period. Multi-slice wT1 mapping was performed using a Dixon-based continuous inversion-recovery Look-Locker (CIR-LL) sequence covering the entire liver in a single breath-hold. Single-slice T1-MOLLI and whole-liver proton density fat fraction (PDFF) and T2* mapping were acquired for comparison. Regions of interest (ROIs) were placed on PDFF, T2*, and wT1 maps in all liver segments. Statistical analysis included intraclass correlation coefficient (ICC; [2, 1]), linear regression, Pearson correlation coefficients Bland-Altman plots and paired two-sided Results: Hydration resulted in a higher global increase in mean liver wT1 (before: 773.4±63.2 ms, after: 800.3±66 ms) than T1-MOLLI (before: 853±68.8 ms, after: 861.6±55.9 ms). PDFF, T2*, and liver stiffness varied modestly within the physiological range. For liver stiffness, T1-MOLLI, and wT1, measurements obtained before and after hydration showed good agreement, with wT1 (y=0.9x+80.5, r=0.89, P<0.001) exhibiting a regression coefficient closer to that of liver stiffness (y=0.9x+0.7, r=0.63, P<0.001) than T1-MOLLI (y=0.6x+372.4, r=0.71, P<0.001). T1-MOLLI and wT1 showed good agreement under both hydration conditions (before: y=0.5x+355.7, r=0.64, after: y=0.8x+98.9, r=0.78), with T1-MOLLI yielding systematically higher values than wT1. Paired analysis demonstrated significant hydration-related changes in wT1 (P<0.001), with segment-wise wT1 increases remaining significant after correction for multiple testing. Furthermore, wT1 revealed spatial heterogeneity across liver segments. Conclusions: Liver wT1 is physiologically modulated by hydration and exhibits spatial heterogeneity across liver segments, even in the healthy liver. These findings underscore the importance of whole-liver, segment-resolved wT1 mapping and physiological standardization when interpreting quantitative liver MRI.

Indexed as

couinaud segmentshydrationliver T1 mappingquantitative magnetic resonance imaging (quantitative MRI)Water-specific T1 (wT1)

Identifiers

PMID42701614
PMCPMC13545628

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.