Evidence map›Paper›PMID 42701524›Full record

ArticleQuantitative imaging in medicine and surgery2026

Impact of CT slice thickness reduction algorithm on AI-based lung nodule detection in chest CTs of colorectal cancer patients.

Se Ri Kang, Won Gi Jeong, Ji Young Rho, Hyemi Choi, Yun-Hyeon Kim, Ju-Hyung Lee, Gong Yong Jin

Abstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Se Ri Kang *Department of Radiology, Wonkwang University Hospital, Wonkwang University School of Medicine, Iksan, Republic of Korea.ORCID https://orcid.org/0000-0001-8684-3778
Won Gi Jeong *Department of Radiology, Chonnam National University Hwasun Hospital, Chonnam National University Medical School, Hwasun, Republic of Korea.ORCID https://orcid.org/0000-0003-2821-2788
Ji Young RhoDepartment of Radiology, Wonkwang University Hospital, Wonkwang University School of Medicine, Iksan, Republic of Korea.ORCID https://orcid.org/0000-0001-6645-3983
Hyemi ChoiDepartment of Statistics and Institute of Applied Statistics, Jeonbuk National University, Jeonju, Republic of Korea.ORCID https://orcid.org/0000-0002-8806-5911
Yun-Hyeon KimDepartment of Radiology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Republic of Korea.ORCID https://orcid.org/0000-0002-0047-0729
Ju-Hyung LeeDepartment of Preventive Medicine, Institute for Medical Sciences, Jeonbuk National University Medical School, Jeonju, Republic of Korea.ORCID https://orcid.org/0000-0003-2487-4098
Gong Yong JinDepartment of Radiology, Research Institute of Clinical Medicine of Jeonbuk National University-Biomedical Research Institute of Jeonbuk National University Hospital, Jeonju, Republic of Korea.ORCID https://orcid.org/0000-0002-1426-554X

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This retrospective multicenter study evaluated whether deep learning-based super-resolution (SR) reconstruction can enhance structural conspicuity in thick-section chest computed tomography (CT) and improve the detection performance of an artificial intelligence (AI)-based computer-aided detection (CAD) system for lung nodules in 96 patients with colorectal cancer (CRC) undergoing chest CT for metastatic surveillance. Pulmonary nodules <10 mm and ≤3 per patient were analyzed. Three image sets were evaluated using a commercial AI-CAD system: original thin-section images (reference), original 5-mm thick-section images, and SR-converted thin-section images. Nodule- and patient-level detection performances were compared using the Cochran-Mantel-Haenszel test and aligned rank transform analysis of variance (ART-ANOVA). Quantitative nodule metrics, image noise, and morphologic consistency were assessed between original and SR-converted thin-section images. Among 105 reference nodules, AI sensitivity increased from 31.4% with thick-section images to 61.0% with SR-converted images, and positive predictive value (PPV) increased from 42.9% to 80.0%. Patient-level sensitivity improved from 41.5% to 67.1%. SR reconstruction reduced image noise (P<0.001) and preserved nodule morphology, with 95.3% anatomic concordance and 80% solid-feature consistency. Nodule size remained comparable; however, density was lower in converted images. SR reconstruction generated 20% hallucinated nodules (16/80), predominantly benign or artifactual structures. In conclusion, SR reconstruction enhances AI-based pulmonary nodule detection by compensating for structural detail lost in thick-section CT. Despite hallucinated nodules, SR reconstruction may provide a feasible harmonization strategy for retrospective multicenter AI research using heterogeneous CT datasets, although further validation in larger populations is required.

Indexed as

Artificial intelligence (AI)chest computed tomography (chest CT)pulmonary nodulesuper-resolution reconstruction (SR reconstruction)

Identifiers

PMID42701524
PMCPMC13545582

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.