Evidence map›Paper›PMID 42699564›Full record

ArticleFrontiers in sleep2026

Personalized comfort settings in positive airway pressure machines using a causal inference approach: a retrospective observational analysis.

Chinh Nguyen, Himani Jayawardane, Hussein Emami, Nathan Liu, Bhavana Achary, Jeff Armitstead, Alison Wimms

Abstract read
In one paragraph

Article in Frontiers in sleep, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Chinh Nguyen *Data Science & AI Lab, Resmed, Sydney, NSW, Australia.
Himani Jayawardane *Data Science & AI Lab, Resmed, Sydney, NSW, Australia.
Hussein EmamiData Science & AI Lab, Resmed, Sydney, NSW, Australia.
Nathan LiuResmed Science Center, Sydney, NSW, Australia.
Bhavana AcharyResmed Science Center, Singapore, Singapore.
Jeff ArmitsteadResmed Science Center, Sydney, NSW, Australia.
Alison WimmsResmed Science Center, Sydney, NSW, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Introduction: To evaluate whether data-driven personalization of positive airway pressure (PAP) comfort settings improves adherence by developing and evaluating a causal machine learning (ML) model for individualized recommendations. Methods: The model was developed using AirSense 10 data and independently validated in temporally separated AirSense 10 and AirSense 11 cohorts, including 90-day and 1-year follow-up. The primary outcome was Centers for Medicare & Medicaid Services (CMS)-defined PAP adherence (device usage ≥ 4 h/night on ≥ 70% of nights during the first 90 days). Group-level average treatment effect (ATE) was estimated using backdoor adjustment methods. A causal forest model was applied to estimate the conditional average treatment effect for recommending personalized settings. A propensity score-matched analysis compared outcomes between patients whose actual settings matched model recommendations vs. those remaining on device default settings. Results: The model estimated ATE at the group level was 2.9 percentage points (p < 0.001), indicating that personalized settings were associated with improved CMS adherence. Covariate balance was achieved (standardized mean difference < 0.1), and model calibration was strong (expected calibration error 0.91%). Patients whose actual PAP settings matched the model-recommended configuration had higher device usage than matched controls who remained on default settings. Subgroup analyses confirmed consistent benefits across age groups, gender, apnea-hypopnea index, and mask type. SHapley Additive exPlanations analysis identified minimum pressure, start pressure and age as key drivers of personalization. Independent validation showed sustained usage benefits across AirSense 10 and AirSense 11 cohorts, with residual AHI remaining below the clinical reference threshold and no clinically meaningful deterioration in mask leak. Discussion: Causal ML-based personalization of PAP comfort settings was associated with improved CMS adherence/device usage. Integration of comfort setting personalization into setup workflows may enhance PAP therapy usage. As a retrospective observational analysis, these findings are associative and hypothesis-generating; the causal-inference framework, refutation testing, and large-scale independent validation provide robustness beyond that of conventional observational studies, although prospective randomized evaluation remains the definitive next step.

Indexed as

adherencecausal inferencecomfort settingscontinuous positive airway pressuremachine learningobstructive sleep apneapersonalized therapy

Identifiers

PMID42699564
PMCPMC13543805

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.