ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology2026

Dosimetric validation of biaxially rotational dynamic-radiation therapy using an O-ring linear accelerator.

Takahiro Aoyama, Tomoki Kitagawa, Yutaro Koide, Yasunori Ishiguro, Ryoma Tomoda, Shingo Hashimoto, Hiroyuki Tachibana, Takeshi Kodaira

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Takahiro AoyamaDepartment of Radiation Oncology, Aichi Cancer Center Hospital, Nagoya, Japan.
Tomoki KitagawaDepartment of Radiation Oncology, Aichi Cancer Center Hospital, Nagoya, Japan.
Yutaro KoideDepartment of Radiation Oncology, Aichi Cancer Center Hospital, Nagoya, Japan.
Yasunori IshiguroDepartment of Radiation Oncology, Aichi Cancer Center Hospital, Nagoya, Japan.
Ryoma TomodaDepartment of Radiation Oncology, Aichi Cancer Center Hospital, Nagoya, Japan.
Shingo HashimotoDepartment of Radiation Oncology, Aichi Cancer Center Hospital, Nagoya, Japan.
Hiroyuki TachibanaDepartment of Radiation Oncology, Aichi Cancer Center Hospital, Nagoya, Japan.
Takeshi KodairaDepartment of Radiation Oncology, Aichi Cancer Center Hospital, Nagoya, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Biaxially rotating O-ring linear accelerators equipped with biaxially rotating gantry-ring mechanics enable non-coplanar arc delivery without the need for couch rotation. This architecture is intended to achieve conformal dose distributions and enable efficient non-coplanar delivery compared with couch-rotated techniques. However, clinical implementation requires dosimetric verification to confirm delivery accuracy. This study aimed to validate the dosimetric accuracy and treatment efficiency of a biaxially rotating O-ring linac using AAPM Task Group (TG)-119 and TG-244 test cases, with reference to TG-218 acceptance criteria. Materials and methods: In this retrospective phantom-based dosimetric validation study, 26 treatment plans were generated in RayStation based on TG-119 and TG-244 and delivered as coplanar VMAT (cVMAT) or non-coplanar VMAT [dynamic swing arc (DSA)]. Point dose measurements were performed with an A1SL ionisation chamber, and dose distribution verification was conducted using the Delta4 Phantom+. Monitor units (MU) and beam-on time (BOT) were compared between cVMAT and DSA. Results: All plans met the ±3% tolerance for absolute point-dose error (measured Conclusions: This study demonstrated dosimetric validation of a biaxially rotating O-ring linear accelerator using TG-119 and TG-244 test cases. The system achieved high accuracy in both cVMAT and DSA deliveries, supporting the dosimetric readiness for clinical implementation.

Indexed as

biaxially rotating O-ring linacdosimetric validationnon-coplanar VMATphantom studyquality assuranceTG-119TG-218TG-244

Identifiers

PMID42699165
PMCPMC13544033

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.