Evidence map›Paper›PMID 42699012›Full record

ArticleEJIFCC2026

Integration of Patient-Based Real-Time Quality Control with Conventional Internal Quality Control: Improved Error Detection and Cost-Benefit Analysis in a Clinical Laboratory.

Mudasir Bashir Dandroo, Devanatha Desikan V, Ramesh Ramasamy

Abstract read
In one paragraph

Article in EJIFCC, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Mudasir Bashir DandrooDepartment of Biochemistry, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India.
Devanatha Desikan VDepartment of Biochemistry, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India.
Ramesh RamasamyDepartment of Biochemistry, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Internal Quality control (IQC) is essential as it ensures analytical accuracy. However, IQC may have certain limitations, for example, it may miss intermittent or matrix-related errors. Patient-Based Real-Time Quality Control (PBRTQC) can overcome this limitation by continuously monitoring the patient data and also aids in early detection of shifts. Hence, integration of PBRTQC with IQC enhances the error detection and the cost efficiency in clinical laboratories. Aim: To study the effect of integrating Patient-Based Real-time Quality Control with Conventional Quality Control for improved detection of errors, cost benefit and risk-based cost benefits. Methods: Four parameters, creatinine, urea, Aspartate Transaminase (AST), and Thyroid Stimulating Hormone (TSH), were selected based on low sigma value and high monthly sample load. Historical patient data was collected from the laboratory information system. Data was divided into training and validation sets. Truncation limits were calculated using the interquartile range method. Simple Moving Average (SMA) was calculated for various block sizes. Control limits were set using the maximum/minimum of the moving average or percentiles. A bias simulation study was performed by introducing bias from -50% to +50% to plot bias detection curves and determine the optimum block size and ANPed. Optimized PBRTQC parameters were validated. The optimized algorithm was applied to daily patient data and integrated with IQC. Moving average alarm rate and percentage increase in error detection were calculated. Potential cost-benefit and risk-based benefits were determined. Results: optimum block size and (ANPed) at TEa was 50 for creatinine (161), 25 for urea (207), 50 for AST (22), and 25 for TSH (68). The MA alarm percentage remained below 1% for all analytes. Integration improved error detection by 28.57% for creatinine, 25% for urea, and 20% for TSH. Net cost benefit demonstrated total savings of 426.92 through QC reductions (264.56) and avoided reanalysis costs (162.36). Conclusion: PBRTQC integration with IQC significantly improves error detection for low sigma performance assays, is cost-effective and provides a strong risk-based cost-benefit advantage.

Indexed as

Average number of patients data required for error detection (ANPed)Bias DetectionClinical BiochemistryClinical Laboratory Improvement Amendments (CLIA)Cost-Benefit AnalysisError DetectionInternal Quality Control (IQC)Laboratory Quality ManagementMoving Average (MA)Patient-Based Real-Time Quality Control (PBRTQC)Risk ManagementSigma MetricsTruncation Limits

Identifiers

PMID42699012
PMCPMC13543464

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.