Evidence map›Paper›PMID 42694059›Full record

ArticleBMJ connections surgery2026

Preliminary clinical experience using the Leica ARveo with MyVeo in neurosurgery: an IDEAL stages 1 and 2a observational study.

Fumihiro Matano, Yohei Nounaka, Hiroyuki Dan, Takao Kitamura, Tadashi Higuchi, Katsuya Umeoka, Yasuo Murai

Abstract read
In one paragraph

Article in BMJ connections surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Fumihiro MatanoDepartment of Neurological Surgery, Nippon Medical School, Bunkyo, Japan.ORCID https://orcid.org/0000-0002-0760-5024
Yohei NounakaDepartment of Neurological Surgery, Nippon Medical School, Bunkyo, Japan.ORCID https://orcid.org/0000-0002-9858-6083
Hiroyuki DanDepartment of Neurological Surgery, Nippon Medical School, Bunkyo, Japan.
Takao KitamuraDepartment of Neurological Surgery, Nippon Medical School, Bunkyo, Japan.
Tadashi HiguchiDepartment of Neurological Surgery, Nippon Medical School, Bunkyo, Japan.
Katsuya UmeokaDepartment of Neurological Surgery, Nippon Medical School, Bunkyo, Japan.
Yasuo MuraiDepartment of Neurological Surgery, Nippon Medical School, Bunkyo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To report the initial clinical experience with the Leica ARveo system with MyVeo in neurosurgery, focusing on feasibility, ergonomics and visualisation characteristics during early clinical implementation. Design: This observational study was conducted in accordance with the IDEAL framework (stages 1 and 2a: Idea/Development and Exploration). Setting: Department of Neurological Surgery, Nippon Medical School Hospital, Tokyo, Japan. Participants: Six patients undergoing neurosurgical procedures, including three aneurysm clippings, two microvascular decompressions and one superficial temporal artery-to-middle cerebral artery bypass for moyamoya disease. Intervention: MyVeo was used either by the assistant (cases 1-3) or collaboratively by the primary surgeon and assistant (cases 4-6), reflecting staged clinical implementation. Main outcome measures: Feasibility, ergonomics, visualisation characteristics, operative workflow and intraoperative safety were assessed based on intraoperative observations and team feedback. Results: All procedures were completed without intraoperative complications. MyVeo allowed flexible viewing and facilitated shared visualisation among surgical team members, with reported improvements in ergonomics and intraoperative collaboration. However, limitations were identified, including lower image resolution and depth perception compared with conventional microscopes as well as neck fatigue and workflow challenges related to cable management. The system required adaptation during use, particularly in the early phase. Conclusions: The use of Leica ARveo with MyVeo was feasible in this small case series and provided ergonomic and collaborative advantages in selected scenarios. However, given its current limitations in visualisation performance and system integration, it should be considered a complementary tool rather than a replacement for conventional operating microscopes. Further studies with objective outcome measures are required to define its clinical role.

Indexed as

NeurosurgerySurgical Equipment and Devices

Identifiers

PMID42694059
PMCPMC13537477

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked