ArticleSmall methods2026
Towards High-Throughput Testing of Bipolar Plate Materials for Proton Exchange Membrane Water Electrolyzers: Correlative Contact Resistance and Stability Analysis.
Article in Small methods, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
Abstract
Bipolar plates (BPP) are a major cost driver in proton exchange membrane water electrolyzers for green hydrogen production that require replacement with more cost-effective materials. However, novel materials must combine high corrosion resistance and low dissolution rates with low interfacial contact resistance (ICR). Herein, we introduce a correlative workflow for determining electrochemical dissolution using a scanning flow cell coupled on-line to an inductively coupled plasma spectrometer and ICR, utilizing a novel miniaturized ICR setup with a sample diameter of 2 mm. The applicability of the setup is demonstrated using titanium (Ti), for which the ICR is found to increase depending on the applied oxidation potential. Furthermore, automated ICR mapping across pristine Ti sheets with a platinum (Pt) coating featuring a thickness gradient reveals a pronounced ICR decrease when the Pt layer exceeds ∼3.8 ± 1.4 nm
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.