Evidence map›Paper›PMID 42693332›Full record

ArticleJournal of imaging informatics in medicine2026

Multi-centre Validation of Automated Outer-to-Outer Wall Segmentation of Infrarenal Abdominal Aortic Aneurysms Using a nnU-Net Based Model.

Cas H F Hendricks, Willemina A van Veldhuizen, Amin Ranem, Bram Fioole, Rogier H J Kropman, Jelmer M Wolterink, Jean-Paul P M de Vries

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of imaging informatics in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Cas H F HendricksDivision of Vascular Surgery, Department of Surgery, University Medical Centre Groningen, Hanzeplein 1, Groningen, 9700 RB, the Netherlands. c.h.f.hendricks@umcg.nl.ORCID http://orcid.org/0009-0005-1140-6609
Willemina A van VeldhuizenDivision of Vascular Surgery, Department of Surgery, University Medical Centre Groningen, Hanzeplein 1, Groningen, 9700 RB, the Netherlands.
Amin RanemDepartment of Applied Mathematics, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
Bram FiooleDivision of Vascular Surgery, Department of Surgery, Maasstad Hospital, Rotterdam, the Netherlands.
Rogier H J KropmanDivision of Vascular Surgery, Department of Surgery, St. Antonius Hospital, Nieuwegein, the Netherlands.
Jelmer M WolterinkDepartment of Applied Mathematics, Technical Medical Centre, University of Twente, Enschede, the Netherlands.
Jean-Paul P M de VriesDivision of Vascular Surgery, Department of Surgery, University Medical Centre Groningen, Hanzeplein 1, Groningen, 9700 RB, the Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Accurate outer-to-outer wall aortic segmentation is essential for abdominal aortic aneurysm (AAA) assessment and endovascular aneurysm repair (EVAR) planning, yet manual segmentation is time-consuming and impractical for routine use. This study aimed to validate a pre-trained open-source nnU-Net-based model for fully automated outer-to-outer wall segmentation of the abdominal aorta in AAA patients. In this retrospective multicentre observational validation study, 75 consecutive AAA patients (25 per centre) from three Dutch hospitals were included. Manual segmentations of pre-EVAR CTA scans were performed. A second observer independently segmented 30 cases to assess interobserver variability. Manual and automatic segmentations were compared using the Dice similarity coefficient (DSC), Jaccard index, maximum and 95th percentile Hausdorff distances (HD max, HD95), mean surface distance, and absolute and relative volume difference. Agreement was assessed for the full abdominal aorta and the infrarenal neck separately. Automatic segmentation achieved excellent agreement with manual segmentations, with a median DSC of 0.97 (IQR 0.96-0.97) and median HD95 of 5.5 (IQR 3.8-7.6) mm. The mean volume bias was 2.06 ml. Performance was comparable to interobserver variability between manual segmentations (median DSC 0.96 [IQR 0.95-0.97]). For the infrarenal neck, a median DSC of 0.95 (IQR 0.93-0.96) was achieved. Automatic segmentation required less than one minute per scan on a dedicated GPU, compared to 45-60 minutes for manual segmentation. Automated outer-to-outer wall aortic segmentation using a pre-trained nnU-Net-based model achieves excellent agreement with manual segmentations, comparable to interobserver variability, across a consecutive multicentre dataset. This approach may support more reproducible and efficient AAA analysis in clinical and research settings.

Indexed as

Abdominal aortic aneurysmAortic segmentationDeep learningEndovascular aneurysm repairImage segmentationnnU-Net

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.