Evidence map›Paper›PMID 42693327›Full record

ArticleOphthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)2026

Objective Assessment of Intermittent Exotropia Magnitude and Control Using the Binocular Eye Alignment Monitor.

Erin C Jenewein, Christopher J Morris, Mitchell Scheiman, Tara L Alvarez

Abstract read
PubMed Publisher
In one paragraph

Article in Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Erin C JeneweinPennsylvania College of Optometry at Drexel University, Elkins Park, Pennsylvania, USA. ej468@drexel.edu.ORCID http://orcid.org/0000-0003-4683-2796
Christopher J MorrisDepartment of Biomedical Engineering, New Jersey Institute of Technology, Newark, New Jersey, USA.
Mitchell ScheimanPennsylvania College of Optometry at Drexel University, Elkins Park, Pennsylvania, USA.
Tara L AlvarezDepartment of Biomedical Engineering, New Jersey Institute of Technology, Newark, New Jersey, USA.

Funding

NEI NIH HHS NEI- R01EY023261
6 · The paper itself

Abstract

purposeTo compare an objective assessment of intermittent exotropia (IXT) control and deviation size using the binocular eye alignment monitor (BEAM) to standard clinical assessments.

methodsIXT control and deviation size were evaluated in 15 participants aged 8-35 years. Participants completed two visits that included a 90-min BEAM eye movement recording at a distance (6 m) to evaluate distance IXT size and control of the deviation objectively. IXT control was assessed using the mean of three measurements of the IXT Office Control Scale, and the deviation size was measured with the prism alternate cover test (PACT).

resultsThe mean IXT control score in the IXT participants was 2.2 ± 1 points, which was weakly correlated with the percentage of time strabismic as measured by the BEAM (Spearman's correlation coefficient = 0.29; p = 0.30). Distance PACT and mean BEAM deviation size demonstrated a moderate, non-significant association (ρ = 0.47, p = 0.08). BEAM measurements were consistently smaller than PACT measurements. IXT distance control (0.44; 95% CI: 0.04-0.80; p = 0.03) and the median deviation size measured by the BEAM (z = -2.1, p = 0.03) were significantly different between visits 1 and 2 (z = -2.1, p = 0.03); however, the percentage of time deviated (BEAM) was not significantly different between the two study visits (z = -0.63; p = 0.50).

conclusionsThe notable differences in control observed with the BEAM compared to current clinical measures suggest that office control scores and prolonged objective monitoring may capture different aspects of IXT control. Objective monitoring over extended periods may be a valuable complement to traditional clinical assessment in both research and clinical care.

Indexed as

Eye movement recordingIntermittent exotropiaIntermittent exotropia controlObjective eye movements

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.