Evidence map›Paper›PMID 42693193›Full record

ArticleInternational orthopaedics2026

Long-term results of a vitamin E-blended polyethylene liner in total hip arthroplasty: a minimum ten year computer aided design based evaluation of wear and component positioning.

Eren Demir, Mahfuz Rasuli, Michael Nienhaus, Philipp Schippers, Martin Naisan, Yazan Noufal, Philipp Drees, Yama Afghanyar

Abstract read
In one paragraph

Article in International orthopaedics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Eren DemirDepartment of Orthopaedics and Traumatology, University Medical Center of the Johannes Gutenberg University, Mainz, Germany. eren.demir@unimedizin-mainz.de.
Mahfuz RasuliDepartment of Orthopaedics and Traumatology, Johannes Gutenberg University Mainz, Mainz, Germany.
Michael NienhausDepartment of Orthopaedics and Traumatology, Johannes Gutenberg University Mainz, Mainz, Germany.
Philipp SchippersDepartment of Orthopaedics and Traumatology, Johannes Gutenberg University Mainz, Mainz, Germany.
Martin NaisanDepartment of Orthopaedic Surgery, St. Josefs Hospital, Wiesbaden, Germany.
Yazan NoufalDepartment of Orthopaedic Surgery, St. Josefs Hospital, Wiesbaden, Germany.
Philipp DreesDepartment of Orthopaedics and Traumatology, Johannes Gutenberg University Mainz, Mainz, Germany.
Yama AfghanyarDepartment of Orthopaedics and Traumatology, Johannes Gutenberg University Mainz, Mainz, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAseptic loosening remains a leading cause of revision in total hip arthroplasty (THA), with polyethylene wear representing a key contributing factor. Vitamin E-blended highly cross-linked polyethylene (VEPE) has been introduced to improve oxidative stability and long-term wear performance; however, long-term clinical data remain limited.

methodsThis retrospective study evaluates long-term polyethylene wear and component positioning in a cohort of patients who underwent primary THA using a vitamin E-blended polyethylene monoblock acetabular component (RM Pressfit vitamys®). Patients were followed for a minimum of ten years. Radiographic assessment was performed using a fully automated, observer-independent CAD-based software (RayMatch®), enabling measurement of cup inclination, anteversion, and polyethylene wear through 2D-3D registration of implant CAD models.

resultsA total of 57 hips with complete radiographic follow-up were analyzed. Mean polyethylene wear rates were 26.9 µm/year at five years and 18.2 µm/year at ten years, remaining well below commonly reported thresholds associated with osteolysis. Cup inclination remained stable over time, whereas a gradual increase in measured anteversion was observed during follow-up.

conclusionAt a minimum ten year follow-up, the investigated vitamin E-blended polyethylene monoblock cup demonstrated favorable long-term wear characteristics and stable component positioning. Further comparative studies are warranted to compare its long-term performance with other acetabular cup and liner designs.

Indexed as

Arthroplasty, Replacement, HipComputer-Aided DesignHip ProsthesisPolyethyleneProsthesis DesignVitamin EAcetabulumAdultAgedAged, 80 and overFemaleFollow-Up StudiesHip JointHumansMaleMiddle AgedPolyethyleneVitamin EAcetabular component positioningPolyethylene wearTotal hip arthroplastyVitamin E–blended polyethylene

Identifiers

PMID42693193
PMCPMC13619713

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.