Evidence map›Paper›PMID 42691025›Full record

ArticlePloS one2026

Lighthouse-shaped rapid identification device for acidic electrolyzed oxidizing water: A low-cost detection method based on conductivity differences.

Yuan Mao, Wei Zheng, Qian Chen

Abstract read
In one paragraph

Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Yuan MaoCentral Sterile Supply Department, 363 Hospital, Chengdu, China.
Wei ZhengCentral Sterile Supply Department, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital &Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China.
Qian ChenCentral Sterile Supply Department, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital &Institute, Sichuan Cancer Center, Affiliated Cancer Hospital of University of Electronic Science and Technology of China, Chengdu, China.ORCID https://orcid.org/0009-0008-1066-9660

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo address the safety risk of mistaking tap water or purified water for acidic electrolyzed oxidizing water (AEOW) during manual cleaning in central sterile supply departments (CSSDs), this study aimed to develop a low-cost, rapid identification device based on electrical conductivity differences to ensure the accuracy and safety of the disinfection process.

methodsA lighthouse-shaped rapid identification device (LRID) was fabricated based on the significantly higher electrical conductivity of AEOW compared with tap water and purified water. Centered on an Arduino Nano microcontroller, the device integrates a conductivity sensor, a wireless charging module, and an LED indication system. It achieves automatic discrimination by detecting liquid electrical conductivity: the green LED remains illuminated for AEOW, while the red LED lights up for tap water or purified water. Identification accuracy, battery life, and waterproof performance were evaluated, and the satisfaction of CSSD technicians with the conventional pH test strip method and the LRID was compared.

resultsThe LRID achieved 100% identification accuracy (90/90) for AEOW, tap water, and purified water collected from the CSSDs of 10 hospitals. The average battery life was 83.75 ± 1.27 h, supporting a weekly charging schedule. All devices functioned normally after continuous immersion in AEOW for 30 days, confirming reliable waterproof performance. Scores from 28 CSSD technicians showed that the LRID was significantly superior to the pH test strip method in identification accuracy, ease of operation, and promotability (P < 0.001).

conclusionThis study successfully developed and validated a low-cost (approximately 20 USD), highly reliable, and easy-to-operate AEOW rapid identification device. The LRID effectively prevents disinfection failures caused by liquid misuse in CSSDs and holds significant potential for its application and promotion.

Indexed as

DisinfectionWaterElectric ConductivityElectrolysisHydrogen-Ion ConcentrationOxidation-ReductionWater

Identifiers

PMID42691025
PMCPMC13541191

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.