Evidence map›Paper›PMID 42690570›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2026

Procedural performance and safety of a helix locking tool for left bundle branch pacing: a prospective multicenter study.

Diego Menéndez, Ermengol Vallès, Álvaro Marco Del Castillo, Haritz Arrizabalaga, Teresa Moraleda, Pablo Elpidio, Guillermo Gutierrez, Eduardo Franco, Cristina Lozano-Granero

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Diego MenéndezArnau de Vilanova University Hospital, Av. Rovira Roure 80, Lleida, 25198, Spain. demenendez.lleida.ics@gencat.cat.ORCID http://orcid.org/0009-0004-5464-2567
Ermengol VallèsHospital del Mar, Barcelona, Spain.ORCID http://orcid.org/0000-0001-5474-8274
Álvaro Marco Del Castillo12 de Octubre University Hospital, Madrid, Spain.ORCID http://orcid.org/0000-0002-5322-2067
Haritz ArrizabalagaBasurto University Hospital, Bilbao, Spain.ORCID http://orcid.org/0000-0001-9478-9409
Teresa MoraledaJuan Ramon Jiménez University Hospital, Huelva, Spain.ORCID http://orcid.org/0000-0002-7114-973X
Pablo ElpidioHospital Clínico de Valladolid, Valladolid, Spain.
Guillermo GutierrezReina Sofia University Hospital, Córdoba, Spain.ORCID http://orcid.org/0000-0002-0121-214X
Eduardo FrancoRamon y Cajal University Hospital, Madrid, Spain.ORCID http://orcid.org/0000-0003-2606-8823
Cristina Lozano-GraneroRamon y Cajal University Hospital, Madrid, Spain.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeHelix retraction during septal lead deployment can complicate left bundle branch pacing (LBBP) procedures performed with extendable-retractable helix leads. A helix locking tool (HLT) has been developed to stabilize the helix of a stylet-driven lead during implantation, but clinical performance data remain limited. This study aimed to evaluate the acute safety and procedural performance of this tool in a multicenter setting.

methodsIn this prospective multicenter registry, 87 consecutive patients who underwent LBBP were enrolled in eight centers in Spain. Implantation was performed using a stylet-driven Tendril STS lead and CPS Direct 3D sheath, with the HLT used during septal deployment. The primary endpoint was freedom from acute adverse events related to the HLT. Secondary endpoints included procedural success, lead repositioning, and acute electrical parameters.

resultsLBBP was successfully achieved in 79 of 87 patients (90.8%). Lead repositioning was required in 36 cases (41.4%), with a mean of 2.3 ± 1.3 attempts. No cases of helix retraction were observed. Three intraprocedural lead dislodgements (3.4%) occurred and were managed without clinical consequences. No acute complications related to the HLT were reported. Electrical parameters were compatible with conduction system capture.

conclusionsIn this prospective multicenter registry, left bundle branch capture was achieved in 79 of 87 patients (90.8%). No helix retraction or acute adverse events considered related to the HLT by site investigators were observed during 24-hour follow-up. In the absence of a comparator group, the study cannot determine whether the HLT reduces helix retraction or improves procedural outcomes.

Indexed as

Conduction system pacingHelix locking toolLeft bundle branch pacingProcedural performanceStylet-driven lead

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.