ArticleVeterinary research communications2026
Comparison of 30° and 70° arthroscopes in canine hip arthroscopy: a 3D-printed model study.
Article in Veterinary research communications, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Hip arthroscopy is a valuable diagnostic and surgical tool in veterinary medicine; however, the optimal arthroscope viewing angle for the canine coxofemoral joint has not been established. We hypothesised that a 70° arthroscope would provide superior visualisation of the hip joint cavity compared to the standard 30° arthroscope when inserted via a dorso-lateral approach. To test this hypothesis, five 3D-printed canine hip joint models were developed using computed tomography (CT) scans of large-breed dogs. The articular surfaces were embossed with a 1 × 1 mm checkerboard pattern to enable objective quantification of the visible area. Arthroscopy was performed with 2.7-mm-diameter 30° and 70° arthroscopes at four positions (3, 6, 9, and 12 o'clock), and the visible area was calculated by counting visible tiles. Statistical analysis was performed using a mixed-effect general linear model. There was no significant overall difference in the visible area between the two arthroscope viewing angles (P = 0.977). However, arthroscope position significantly affected the visible area (P < 0.001), and a significant interaction between viewing angle and position was identified (P = 0.001). Notably, the visible area produced by the 70° arthroscope was significantly smaller than that produced by the 30° arthroscope at the 12 o'clock position (P = 0.026). However, at the 3 o'clock position, the visible area produced by the 70° arthroscope appeared to be larger than that produced by the 30° arthroscope. Nevertheless, this difference was not significant (P = 0.085). The results suggest that, in this experimental model, the 70° arthroscope provided a comparable overall visible area of the artificial hip joint surface to the 30° arthroscope during dorso-lateral canine hip arthroscopy. Further comparative studies, particularly on calibrated cadaveric hip joints, are required.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.