ArticleJournal of dental sciences2026

Biomechanical effects of titanium alloy removable partial denture framework designs fabricated by selective laser melting in mandibular Kennedy class II partial edentulism: A finite element study.

Min-Chieh Chang, Ping-Ching Wu, Wei-Shao Lin, Yung-Chung Chen

Abstract read
In one paragraph

Article in Journal of dental sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Min-Chieh ChangDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
Ping-Ching WuDepartment of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan.
Wei-Shao LinDepartment of Prosthodontics, Indiana University School of Dentistry, Indianapolis, IN, USA.
Yung-Chung ChenDivision of Prosthodontics, Department of Stomatology, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/purpose: The biomechanical effects of framework design and material interactions in mandibular free-end saddle removable partial dentures remain unclear. This study evaluated framework variables using finite element analysis. Materials and methods: A mandibular Kennedy Class II model was digitized to create a cobalt-chromium (CoCr) and sixteen Ti-6Al-4V (Ti64) frameworks varying by major connector dimension, clasp configuration, and lingual reciprocal assembly (LRA). Periodontal ligament (PDL) and mucosa layers were incorporated. Contacts were defined, and materials were assumed homogeneous and isotropic. Vertical and oblique loads were applied, and von Mises stresses were analyzed. Model validation was performed using digital image correlation. Results: Ti64 frameworks reduced overall stress by 21%-43% compared with CoCr. Under vertical loading, PDL stress decreased by 40% and framework stress by 32%-46%. Under oblique loading, direct retainer, PDL, and mucosal stresses increased by 3%, 6%, and 13%, respectively. Framework stress distribution was governed by clasp-LRA interaction, whereas increasing connector rigidity reduced stress magnitude and variability rather than peak stress. Supporting tissue responses were primarily determined by major connector dimension, with LRA and clasp effects being design- and loading-dependent. Conclusion: Ti64 frameworks improved load distribution with limited supporting tissue stress increases under oblique loading. Framework behavior was primarily governed by clasp-LRA interaction, while connector dimension determined supporting tissue response. Increasing major connector dimension attenuated LRA-related stress variations, particularly under oblique loading. Coordinated control of clasp configuration, LRA incorporation, and major connector dimension is required for biomechanical optimization.

Indexed as

BiomechanicsFinite element analysisMechanical stressRemovable partial dentureTitanium alloys

Identifiers

PMID42689028
PMCPMC13536343

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.