Evidence map›Paper›PMID 42688622›Full record

ArticleJournal of dental sciences2026

Influence of all-on-4 implant angles on stability and crestal bone - A finite element optimization analysis.

Jing-Jie Chen, Chen-Sheng Chen, Ting-Sheng Lin, Chih-Ling Chang

Abstract read
In one paragraph

Article in Journal of dental sciences, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jing-Jie ChenDepartment of Biomedical Engineering, I-Shou University, Kaohsiung, Taiwan.
Chen-Sheng ChenDepartment of Physical Therapy and Assistive Technology, National Yang Ming Chiao Tung University, Taipei, Taiwan.
Ting-Sheng LinDepartment of Biomedical Engineering, I-Shou University, Kaohsiung, Taiwan.
Chih-Ling ChangDepartment of Prosthodontics, Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background/purpose: The all-on-4 implant technique is a restoration method designed for patients with complete or extensive edentulous, requiring only four implants to support a full-arch denture. However, the inclination angle configuration of implants directly affects force distribution and stability. Therefore, this study employs optimization techniques to investigate the impact of mesial and distal implant angle in mandibular all-on-4 cases on the biomechanics of bone tissue. Materials and methods: This study established three-dimensional models of the mandible, implant, and framework. Finite element (FE) analysis was employed to simulate stress distribution and stability under various angular combinations. Force conditions were set to apply a 200 N vertical bite force at the left canine position and a 250 N oblique bite force at the left first molar position, simulating the maximum vertical and oblique loading scenarios during unilateral mastication. Optimal parameter settings were determined: the mesial implant inclination angle was set between -1.5° and 3°, and the distal implant inclination angle was set between 20° and 30°. The optimization technique identified the angular configuration that maximized bone stress uniformity and stability. Results: Under a 200N vertical bite force, adjusting the implant angles from the original model's distal implant at 30° and mesial implant at 0° to optimized angles (distal implant 20°, mesial implant 2.8°) reduced crestal bone stress by approximately 4 %-12 %. Under a 250N oblique bite force, the optimized angles (distal implant 20.19°, mesial implant 2°) reduced crestal bone stress by approximately 4 %-16 %. Furthermore, the optimized angle can reduce the maximum displacement of the implant under 250 oblique force to 11 %. Conclusion: This study concluded that adjusting the angle of all-on-4 implants to approximately 2° for mesial implants and 20° for distal implants can maintain better stability and effectively reduce stress concentration around the implants.

Indexed as

All-on-4 implantBiomechanical analysisDental implantFinite element analysisOptimization

Identifiers

PMID42688622
PMCPMC13536338

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.