Evidence map›Paper›PMID 42688157›Full record

ArticleFrontiers in bioengineering and biotechnology2026

Biomechanical and clinical comparison of a novel dual-wing locking plate versus the PHILOS plate for neer three- and four-part proximal humeral fractures: a finite element analysis combined with a retrospective cohort study.

Jianhua Ji, Qinggang Zhao, Sixing Wei, Xingxi Hu, Yongcheng Deng, Zhong Chen, Jinyi Gu, Changshun Chen

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jianhua Ji *Department of Orthopaedic and Trauma Surgery, Affiliated Hospital of Yunnan University, Kunming, China.
Qinggang Zhao *Department of Orthopaedic and Trauma Surgery, Affiliated Hospital of Yunnan University, Kunming, China.
Sixing WeiDepartment of Orthopaedic and Trauma Surgery, Affiliated Hospital of Yunnan University, Kunming, China.
Xingxi HuDepartment of Orthopaedic and Trauma Surgery, Affiliated Hospital of Yunnan University, Kunming, China.
Yongcheng DengDepartment of Orthopaedic and Trauma Surgery, Affiliated Hospital of Yunnan University, Kunming, China.
Zhong ChenDepartment of Orthopaedic and Trauma Surgery, Affiliated Hospital of Yunnan University, Kunming, China.
Jinyi GuClinical Laboratory of Affiliated Hospital of Yunnan University, Kunming, China.
Changshun ChenDepartment of Orthopaedic and Trauma Surgery, Affiliated Hospital of Yunnan University, Kunming, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Neer three- and four-part proximal humeral fractures treated with conventional PHILOS plating are associated with high complication rates, primarily due to tuberosity re-displacement and calcar screw cut-out. We developed a novel dual-wing locking plate featuring bilateral tuberosity-capturing wing extensions and an omnidirectional ball-head calcar screw. This study compared its biomechanical performance and clinical outcomes with those of the PHILOS plate. Methods: A three-dimensional finite element model was reconstructed from CT data using Mimics 21.0, Geomagic 2021, and Rhino 7.0, and analyzed in ANSYS 2022R1 under four shoulder abduction angles (0°, 30°, 60°, 90°) with angle-specific physiological rotator cuff loading. Outcome measures included von Mises stress and displacement in the plate and bone, as well as implant stress distribution. Clinically, we reviewed 43 consecutive patients with Neer three- or four-part fractures treated between January 2023 and December 2024: 19 with the dual-wing plate (Group A) and 24 with the PHILOS plate (Group B). Recorded parameters included Visual Analog Scale score, Constant-Murley score shoulder range of motion, fracture union, and complications. Results: Across all abduction angles, peak bone von Mises stress and maximum bone displacement were comparable between constructs (differences <2%). The principal biomechanical difference was stress distribution: the PHILOS plate concentrated peak stress at the proximal calcar screw-plate junction at every angle, whereas the dual-wing plate shifted this concentration to the wing-main plate interface, away from the articular region. Peak plate stress was similar at 0° (42.9 vs. 43.3 MPa) and 30° (59.4 vs. 60.6 MPa), but diverged at 60° (67.2 vs. 82.3 MPa) and 90° (68.4 vs. 108.7 MPa), reflecting progressive wing loading. Clinically, Group A initiated passive pendulum exercises 3.7 days earlier (6.26 ± 0.73 vs. 9.96 ± 1.37 days; p < 0.001), had lower VAS at 1 month (p = 0.005), higher CMS at 1 month (p = 0.003) and 2 months (p < 0.001). No tuberosity nonunion or malunion occurred in Group A versus three cases in Group B. Conclusion: The dual-wing plate does not reduce overall bone stress or displacement but fundamentally redirects implant stress concentration from the calcar screw region to the wing-plate interface. This redistribution was associated with earlier passive pendulum exercise initiation and a lower observed rate of tuberosity complications in this small cohort.

Indexed as

bone healingdual-wing locking platefinite element analysisPHILOS plateproximal humeral fractureretrospective cohort studytuberosity fixation

Identifiers

PMID42688157
PMCPMC13533890

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.